Agilent Technologies 83A, N5161A, 62A, 82A, 81A manual Connecting the AC Power Cord

Page 12

Getting Started

Meeting Environmental and Electrical Requirements

Connecting the AC Power Cord

This is a Safety Class 1 Product provided with a protective earth ground incorporated into the power cord. The front panel switch is only a standby switch; it is not a line switch. The AC power cord is the disconnecting device that disconnects the signal generator mains circuits from the mains supply. Alternatively, an external switch or circuit breaker, readily identifiable and easily reached by the operator, may be used as a disconnecting device.

WARNING The mains plug shall be inserted only in a socket outlet provided with a protective earth contact. Always use the three- prong AC power cord supplied with the signal generator. Personal injury can occur if there is any interruption of the protective conductor inside or outside of the signal generator. Intentional interruption is prohibited.

CAUTION The mains wiring and connectors shall be compatible with the connector used in the premise electrical system. Inadequate earth grounding can damage the signal generator. Always use the three- prong AC power cord supplied with the signal generator.

Connect the AC power cord as follows:

1.Ensure that the power cord is not damaged.

2.Install the signal generator so that one of the following items is readily identifiable and easily reached by the operator: AC power cord, alternative switch, or circuit breaker.

3.Insert the mains plug into a socket outlet provided with a protective earth grounding.

6

Agilent N5161A/62A/81A/82A/83A MXG Signal Generators Installation Guide

Image 12
Contents Installation Guide AU TI O N WA RN ING Contents Regulatory Information Installation Guide User’s Guide Programming Guide Documentation OverviewScpi Reference Service Guide Key Helpa Safety Information General Safety ConsiderationsInstrument Markings ICES/NMBGetting Started Signal Generator Physical Characteristics Checking the ShipmentOption Description Quantity Part Number Line Setting Requirements Meeting Environmental and Electrical RequirementsEnvironment VentilationConnecting the AC Power Cord Configuring the MXG ATE Accessing the MXG ATE Web-Enabled Page1Web-Enabled MXG ATE2 Configuring the Display N5181A/82A/83A Only1 Display SoftkeysConfiguring for Remote Control1 LAN ConfigurationGpib Configuration Enabling LAN Services Browser, Sockets,Ordering Accessories Descriptiona Part Number Part NumberbDescription a Part Number Part Number b Proper Use and Cleaning Returning a Signal Generator to Agilent TechnologiesCleaning Suggestions Contacting AgilentOperation Verification Running Self Test1 Self Test Failure1 Viewing Test ResultsFrequency Range and Accuracy Check Test Equipment Recommended ModelFrequency Counter Procedure N5161A1/62A1/81A/82A Frequency MHz Limit HzSpectrum Analyzer Procedure Frequency Limit HzN5161A/62A N5183A 81A/82A Checking the Output Power Troubleshooting Problems with the Frequency Accuracy CheckN5161A1/81A Test Procedure N5161A/81A Output Power Frequency Amplitude dBm LimitsN5162A1/82A Test Procedure Without ModulationWith Modulation N5183A Test Procedure N5183A Frequency Power SensorN5183A Output Power Frequency Amplitude Limits a DBm Option 1EA520 532 540 40 GHz Option Troubleshooting Problems with the Output Power Check Operation Verification Checking the Output Power Certification AssistanceStatement of Compliance Compliance with Canadian EMC RequirementsCompliance with German Noise Requirements Acoustic Noise Emission/GeraeuschemissionIndex Index

81A, 82A, 83A, 62A, N5161A specifications

Agilent Technologies, now part of Keysight Technologies, is renowned for its advanced electronic test and measurement solutions. Among its offerings, the 83A, N5161A, 62A, 82A, and 81A signal generation and analysis instruments stand out for their performance, reliability, and innovative technologies tailored for various applications.

The Agilent 83A is a versatile RF signal generator designed for lab environments and production lines. Its main features include wide frequency coverage, low phase noise, and frequency accuracy, making it suitable for testing wireless communications, radar, and military applications. The use of advanced digital signal processing ensures high output stability and purity, crucial for testing complex modulation schemes.

The N5161A, part of the EXG series, is a signal generator that combines exceptional performance with extensive functionality. It offers frequency coverage from 250 kHz to 6 GHz and includes capabilities for creating complex waveforms. Its built-in arbitrary waveform generator allows users to define custom signals, enhancing testing versatility. The integrated software support streamlines programming and automation, which is vital for production testing environments.

The Agilent 62A is designed specifically for microwave applications, offering frequency ranges up to 40 GHz. One of its standout features is its ability to generate signals with remarkably low phase noise, making it suitable for applications that require high precision, such as aerospace and defense. It also features multi-channel capability, allowing simultaneous testing of multiple devices, which increases throughput in high-demand environments.

The 82A signal generator is frequently used in educational and research settings due to its user-friendly interface and cost-effectiveness. It provides several modulation options, including AM, FM, and PM, making it an excellent choice for experimentation and learning purposes. The device’s compact design ensures that it fits well in diverse laboratory setups.

Lastly, the Agilent 81A is known for its compact size and portability, making it highly suitable for field applications. It features basic signal generation capabilities and is designed for ease of use, providing engineers with a reliable tool for quick tests and measurements in various locations.

In conclusion, Agilent Technologies' 83A, N5161A, 62A, 82A, and 81A signal generation instruments exemplify innovation in electronic measurement. Each model possesses unique features and capabilities, allowing engineers to choose the right tool for their specific testing needs across numerous industries, from telecommunications to aerospace. With an emphasis on precision, flexibility, and advanced technology, these instruments continue to play a vital role in the evolution of electronic test solutions.