Cornelius R-404A manual ‘‘SYRUP PRIME’’ Switches

Page 9

Side 1

Side 2

BLEND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF

SYRUP PRIME

ERROR

 

 

 

 

ON

RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

 

ER

 

 

Display

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<(Backward)(Forward)>

Cancel Defrost

Manual Defrost

Menu/Select MS

FIGURE 2. CONTROL PANEL SWITCH IDENTIFICATION

‘‘SYRUP PRIME’’ Switches.

The ‘‘SYRUP PRIME’’ switches, located on the control panel, are touch-type switches and require only pressing to activate. The ‘‘SYRUP PRIME’’ switches are used only when filling the syrup systems sold-out floats during syrup replenishing, syrup flavor changeover, or sanitizing the syrup systems.

‘‘BLEND ON/OFF’’ Switches.

The ‘‘BLEND ON/OFF” switches, located on the control panel, are touch-type switches and require only press- ing to activate. These switches are used to fill the product blender tanks after the sold-out floats have been filled using the ‘‘SYRUP PRIME’’ switches. After the product blender tanks have been filled, the “BLEND ON/OFF” switches may be pressed again to prevent more product from entering the product blender tanks during BRIX test. The “ON” and “BLEND ON/OFF” switches must be pressed to operate the freeze cylinders beaters and refrigeration system during normal operation.

‘‘MOTOR’’ Switches.

The ‘‘MOTOR’’ switches, located on the control panel, are touch-type switches and require only pressing to acti- vate. These switches are used to operate the freeze cylinders beaters with no refrigeration during sanitizing.

’’ON’’ Switches.

The ‘‘ON’’ switches, located on the control panel, are touch-type switches and require only pressing to activate. These switches are used to operate the freeze cylinders beaters and refrigeration system after cylinders have been filled with product. The freeze cylinders beaters and refrigeration system may be stopped by pressing the ‘‘OFF’’ switches.

‘‘OFF’’ Switches.

The ‘‘OFF’’ switches, located on the control panel, are touch-type switches and require only pressing to activate. These switches are used to stop freeze cylinders beaters and refrigeration system.

‘‘ERROR RESET’’ Switch.

‘‘ERROR RESET’’ switch, located on the control panel, is a touch-type switch and requires only pressing to acti- vate. The ‘‘ERROR RESET’’ switch is used to restore normal operation after error within Unit (indicated by ‘‘ERROR 1’’ or ‘‘ERROR 2’’ on message display) has been corrected.

312030002

4

Image 9
Contents FCB POST-MIX Dispenser With V4 Features 404A Refrigerant Table of Contents Table of Contents cont’d List of Figures FCB POST-MIX Dispensers with V4 FeaturesThis page Left Blank Intentionally Safety Information This page Left Blank Intentionally Control Panel Keypad Security Control Panel Switches‘‘SYRUP PRIME’’ Switches Operating Controls FOUR-FLAVOR Unit Shown Control Panel Display Messages ‘‘FILL 1’’ and ‘‘FILL 2’’ Fault MessagesDefrost Systems Units Equipped with HOT-GAS Defrost SystemsUnits Equipped with Electric Defrost Systems ‘‘WAKE UP’’ Wake UP Time ‘‘SLEEP’’ Sleep TimeFaceplate Relief Valves Dispensing ValvesDispensed Product Conditions ‘‘OVERRUN’’, AS Applied to Frozen Carbonated BeveragesDrawing Adjusting CO2 Regulators Operating CharacteristicsOperating Unit Primary CO2 RegulatorReplenishing Syrup Supply Adjusting Brix WATER-TO-SYRUP Ratio of Dispensed ProductSecondary CO2 Regulators Syrup Tanks SystemSyrup Flavor Change Replenishing CO2 SupplyBAG-IN-BOX System Daily Cleaning of Unit Cleaning and Sanitizing312030002 312030002 Cleaning Condenser Coil Unit with AIR-COOLED Refrigeration SystemUnit with Remote Condensing Refrigeration Troubleshooting Control Panel Switches and Fault Messages TroubleshootingOperation Troubleshooting Product Blender Tanks and CarbonatorsWater Pump Cycling Troubleshooting Dispensed ProductInstructed Warranty Page One Cornelius Place Anoka, Minnesota 612 800

R-404A specifications

Cornelius R-404A is a synthetic refrigerant blend widely used in various refrigeration and air conditioning applications. Composed primarily of three components—R-125 (44%), R-143a (52%), and R-134a (4%)—this blend is designed to provide effective cooling performance in both commercial and industrial environments. Its popularity can be attributed to its efficient thermodynamic properties, making it a suitable choice for low and medium temperature refrigeration systems.

One of the hallmark features of R-404A is its high energy efficiency. As a refrigerant, it offers excellent performance in heat transfer capabilities, which translates to lower energy consumption and operational costs. R-404A operates effectively within a wide range of evaporating temperatures, allowing it to serve various applications, from refrigerated display cases to cold storage facilities. The refrigerant's low glide temperature helps maintain consistent temperatures in these applications, enhancing food safety and product quality.

R-404A does not belong to the ozone-depleting substances category, making it an environmentally friendly choice. However, it is important to note that R-404A does have a significant global warming potential (GWP) of 3,922, raising concerns regarding its long-term environmental impact. As awareness of climate change increases, industries are shifting towards alternative refrigerants with lower GWPs, but R-404A remains prevalent in many existing systems.

In terms of compatibility, R-404A is non-toxic and non-flammable, making it a safe choice for use in commercial environments. Additionally, it is compatible with oils traditionally used in refrigeration systems, simplifying retrofitting processes when upgrading from other refrigerants. R-404A is also designed to work with standard refrigeration components, ensuring compatibility with existing equipment.

To maximize efficiency and performance when using R-404A, proper system design and maintenance are critical. Regular checks for leaks, appropriate charge levels, and routine maintenance can help extend the life of the system while ensuring optimal performance of R-404A as a refrigerant. As industries continue to adapt to evolving regulations and environmental concerns, the future of R-404A will likely involve the transition to lower-GWP refrigerants, but its robust features and performance continue to make it a staple in the refrigeration landscape.