Trouble |
| Probable Cause |
BEVERAGES NOT SWEET ENOUGH. | A. | Empty syrup tank. |
| B. | Faucet brix requires adjusting. |
|
|
|
BEVERAGES NOT COLD (UNITS WITH | A. | Unit standing with no ice in hopper – no ice in |
COLD PLATE). |
| cold plate cabinet. |
|
|
|
FLAVOR SYRUPS DO NOT DISPENSE. | A. | No 24 volt power to PC board. |
| B. | No CO2 pressure. |
| C. | Empty syrup tank. |
| D. | Kinked tubing. |
| E. | Clogged inner nozzle. |
| F. | Defective PC board. |
| G. | Defective harness from keypad. |
| H. | Defective Flow control. |
| I. | Defective solenoid harness. |
| J. | Defective keypad. |
|
|
|
FLAVOR DISPENSES FOR MORE THAN 1 SEC. | A. | Dip switch settings on control board incorrect. |
| B. | PC board defective. |
| C. | Defective flow control. |
|
|
|
FLAVOR DISPENSES MORE THAN .5 OZ. | A. | Dip switch settings on control board incorrect. |
| B. | Flow control incorrectly set. |
| C. | PC board defective. |
| D. | Defective flow control. |
Contact your local syrup or beverage equipment distributor for additional information and troubleshoot- ing of beverage system.
620917901OPR | 6 |