Cornelius 175 8 Valve manual Dispensing Valves, Product Tubing

Page 5

E.Using a cloth, wash down the surfaces of the cold plate and plastic cover with soap solution.

F.Install and properly position the cover on the cold plate.

G.Install the splash panel in the reverse order it was removed.

H.Rinse cold plate surface by pouring potable water through hopper openings.

2.DISPENSING VALVES

Refer to addendum supplied with the unit that is applicable to the manufacturer of the valves installed on the unit.

3.PRODUCT TUBING

Only trained and qualified persons should perform these cleaning and sanitizing procedures.

A.Sanitize tank systems, Post-Mix and Pre-Mix

a.Remove all the quick disconnects from all the tanks. Fill a suitable pail or bucket with soap solution.

b.Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon bristle brush. (Do not use a wire brush). Rinse with clean water.

c.Prepare sanitizing solution and using a mechanical spray bottle, spray the disconnects. Allow to air dry.

d.Using a clean, empty tank, prepare five (5) gallons of the sanitizing solution. Rinse the tank discon- nects with approximately 9 oz. of the sanitizing solution. Close the tank.

e.Prepare cleaning tank by filling clean five (5) gallon tank with a mixture of mild detergent and pota- ble water (120_ F).

f.Connect a gas disconnect to the tank and then apply one of the product tubes to the cleaning tank. Operate the appropriate valve until liquid dispensed is free of any syrup.

g.Disconnect cleaning tank and hook up sanitizing tank to syrup line and CO2 system.

h.Energize beverage faucet until chlorine sanitizing solution is dispensed through the faucet. Flush at least two (2) cups of liquid to ensure that the sanitizing solution has filled the entire length of the syrup tubing.

i.Allow sanitizer to remain in lines for fifteen (15) minutes.

j.Repeat the step above, applying a different product tube each time until all tubes are filled with the sanitizing solution.

k.For post-mix valves, remove the nozzle and syrup diffuser and clean them in a mild soap solution. Rinse with clean water and reassemble the nozzle and syrup diffuser to the valve.

l.For pre-mix valves, disconnect all product tubes from the tank of sanitizing solution and then open the valves to allow the pressure to be relieved. Remove the valves from the dispenser, disas- semble and wash thoroughly in a mild soap solution.

m.Rinse the parts in clean water, reassemble the valve and reconnect it to the dispenser.

n.Discard the tank of sanitizing solution and reconnect the product (syrup or pre-mix) tanks. Operate the valves until all sanitizer has been flushed from the system and only product (syrup or pre-mix) is flowing.

3

620917901OPR

Image 5
Contents This Document Contains Important Information To the InstallerTable of Contents Cleaning Instructions MaintenanceMonthly START-UP & Operating InstructionsCold Plate Cleaning Interior SurfacesBeverage System if Applicable Product Tubing Dispensing ValvesSanitize syrup lines, B-I-B Systems Troubleshooting Beverages not Cold Units with BUILT-IN Beverages not Sweet EnoughCold Plate Flavor Dispenses More than .5 OZGreece D WarrantyIMI Cornelius INC