CHANGING THE UV GERMICIDAL BULB

10.After base is totally cleaned and dried, replace mineral absorption pad. Place steam dome on base by aligning its slots with tabs in base. (You may have to reposition steam dome to other set of tabs, because it will only fit one way.)

Rotate steam dome clockwise until it locks. Place steam diffuser on base so that the slots in steam diffuser line up with tabs on the base. Rotate steam diffuser clockwise until it locks in place.

11.Replace tanks. Plug in the unit and resume normal use.

CHANGING THE UV GERMICIDAL BULB

1.If the “REPLACE UV BULB” indicator illuminates during normal use, it is time to change the UV germicidal bulb, which is a special 3.5W bulb.

2.Turn the POWER switch to the “OFF” position, unplug it and allow it to cool.

3.Remove the water tanks from the base of the humidifier. Remove steam diffuser and steam dome by rotating them counterclockwise and lift up.

4.Place the base of the humidifier over the sink and tilt the unit to remove any remaining water.

5.Carefully turn the base of the humidi- fier over and place it upside

down on a flat level surface. You will see a door at front of unit that is closed with two Phillips head screws.

6.Using a Phillips head screwdriver, carefully turn the screws counterclockwise until the screws separate from the door.

7.Open the door, by pulling forward. The UV germicidal light bulb will be visible. Pull the door out the minimum amount to have access to unscrew bulb from socket.

8.Take a replacement 3.5W UV germicidal bulb that you purchased from Slant/Fin Corporation or another supplier and change the bulb. To prolong the life of the bulb, limit your direct contact with the glass of the bulb by using a cloth or tissue to screw it into place.

9.When the new bulb is in place, close the door and replace the screws by using your Phillips head screwdriver and rotating them clockwise until they are just tight. DO NOT OVER TIGHTEN.

10.DO NOT turn power on, while UV lamp door is open, and DO NOT view illu- minated bulb directly because eye damage may occur.

11.Turn the unit upright, place the water tanks on top of the base of the humidifi- er, plug the unit in, and turn the POWER switch to either the LO or HI posi- tion. The “REPLACE UV BULB” indicator should no longer be lit.

IMPORTANT NOTE: Even though you will not receive maximum germicidal effects, you can still use your GF-300 and GF-350 humidifier until the replacement bulb arrives.

STORAGE TIPS

If you do not plan to use your humidifier for an extended period of time, such as during the summer months, it is important that you follow these instructions to help prevent problems from developing in the unit.

1.Clean your humidifier as instructed in the section titled, “Cleaning and Maintenance”.

2.Make sure all water is emptied from the tanks and the hot and cold water reservoirs.

3.Dry your unit thoroughly.

4.Leave the tank caps off to expose the tanks to air.

5.Pack your humidifier in its original carton and store it in a cool, dry place.

SERVICE

DO NOT attempt to repair this humidifier yourself. For repairs covered under the warranty, contact Slant/Fin by telephone or mail for a Return Authorization Number.

TROUBLESHOOTING

TROUBLE

POSSIBLE CAUSES

SOLUTION

Unit does not mist

Unit is not plugged in

Plug in unit

 

Power failure

Check circuit breaker

 

Water tanks empty

Remove and refill

 

Power switch not turned on

Turn on switch to LO or HI

 

Unit not reset after refilling tanks

Reposition water tanks

 

Water tank not properly

Reposition water tanks

 

located on base unit

 

 

Humidity level set is achieved

Turn Relative Humidity

 

 

Control to higher setting

 

Using distilled or treated water

Add “pinch” of table salt

 

which does not contain enough

 

 

ions

 

 

Only one tank empties

Move unit to level surface.

 

 

Raise end with full tank.

Water leaks from unit

Drain cap, drain cap gasket,

Tighten cap.

 

tank cap or tank cap

Replace tank cap

 

gasket is missing or improperly

or reposition cap

 

positioned

gasket.

Moist air output low

Mineral buildup in hot water

Clean unit as per

 

reservoir

instructions.

Refil lindicator light on

Water level is below water

Refill water tanks

 

level probes

and mount tanks on base

 

Water level probes

Clean probes per

 

are covered with film

cleaning instructions

 

Mineral buildup in hot water

Clean unit per

 

reservoir

cleaning instructions