location
A minimum clearance of 15cm (6 in) must be left at the sides of the machine for routing cooling air drawn into and exhausted out of the compartment to maintain a proper condensing operation.
Position the ice maker in its final location and make sure that there is everything for its installation, namely:
19
Fused switched power supply.
|
|
|
| GB | english | |
| 26 |
| 33 |
|
| |
|
|
|
| |||
| The electrical isolator switch |
| Water drain is connected |
| ||
| must be fitted with the correct |
| and |
| ||
| fuse rating. |
| spiralled hose which |
|
| |
|
|
|
| should have a minimum |
|
|
|
|
|
| fall of 3cm per metre. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 34 | |
27 |
|
|
|
|
| It is recommended that |
The minimum ambient |
|
|
|
| ||
|
|
|
| the interior of the | ||
temperature should not be |
|
|
|
| storage bin is cleaned | |
lower than +10˚C and the |
|
|
|
| with an appropriate mild | |
maximum ambient |
|
|
|
| disinfectant solution. | |
temperature higher than |
|
|
|
|
| |
+40˚C |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
14
20
Water supply connection with
21
Waste drain water connection.
22
Attention
Make sure that water available is connected to a cold drinking water supply. If in doubt consult the installer for the possible installation of a water filter or water conditioner.
To gain full advantage from this unit in terms of performance and durability also make sure that:
23
Minimum water temperature is not lower than +5˚C and maximum water temperature does not exceed +40˚C.
24
Minimum water pressure is not below 1 bar and maximum water pressure does not exceed 5 bar.
25
The electrical suppy available corresponds to machine specifications as indicated on the unit nameplate.
28
There are no heat sources (kitchen ovens, grills) near the machine and the environment is not too humid.
how the installation is made
Important
The machine installation has to be performed by Authorised Service Personnel
29
Connect the power lead to a suitable electrical supply
30
Check machine is level.
31
The level can be corrected by means of the levelling feet.
32
Make the connection to the water supply using the hoses supplied with the machine.
start up
35
Open water
36
Plug in machine.
37
Switch the main switch to the ON position.At this stage the unit will start up.
38
The Authorised Service Agent will complete an inspection of the unit interior.
The first batch of ice cubes will drop into the storage bin approximately 30
minutes from
be of poor quality but subsequent batches will be good quality.
39
Attention
If the temperature of the room in which the machine is placed is below +15˚C, the freezing cycle length will be shorter (17 to 20 minutes).
40
Alternatively, if the room temperature is above +30˚C, the freezing cycle length will be longer (25 to 30 minutes).
3