Gaggenau AH 530-790, AH 530-720 manual Maintenance

Page 12

5. Maintenance

Fig. 16

Fig. 17

The appliance must be disconnected from the power supply during all repair work.

If the appliance does not function correctly, check the fuses first.

If the power supply is functioning correctly, but your appliance still does not work, please contact your Gaggenau dealer who will provide you with the address and telephone number of your nearest manufacturer’s authorized service agent or contact Gaggenau USA on (800) 828-9165. Specify the appliance type (see rating plate).

Repairs may only be carried out by authorised technicians, in order to guarantee the safety of the appliance.

Unauthorised tampering with the appliance will invalidate any warranty claims.

Only ever use original spare parts.

Lamp replacement

Caution: Disconnect the power supply before replacing lamps (switch off the fuse)!

Caution: Lamps may still be hot shortly after use! Risk of burns.

Detach the ring from the lamp cover.

Note: Make sure that the glass will not fall out (Fig. 16).

Pull out the lamp (Fig. 17).

Defective lamps must only be replaced by lamps of the same type! (12 V/20 W/G4 lampholder)

Inserting the lamp

Insert the lamp in the lampholder.

Note: Do not touch the halogen lamps with your hands. Use a cloth and touch the lamp only on its edges.

Engage the lamp cover.

Connect the appliance to the mains again.

12

Image 12
Contents Page Preface Safety notes Read And Save These Instructions For your safety Important notesOperating for the first time About useFeatures Operation Page Special functions Cleaning and care Page Maintenance Assembly instructions Technical dataInstallation Condensate separator RV 060-150 must be installed Important Before marking the securing holes Page Operating and assembly instructions Extractor hood