Gaggenau AH 530-790, AH 530-720 manual Cleaning and care

Page 10

4. Cleaning and care

Fig. 13

Cleaning the grease filters

The grease filter saturation display F flashes after an operating time of 30 hours to indicate that you should clean the grease filter (see Fig. 3). The grease filter can of course be cleaned at any time, even if the grease filter saturation display should not start to flash.

The stainless steel grease filters can be removed easily for cleaning (see Fig. 13):

Grip the grease filter handle and push the slide towards the rear. Then pull the grease filter downwards out of the holder; repeat the operation for the other grease filters.

You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 150 °F / 65 °C, where it should be supported vertically to allow food or rinsing residues to drain off.

The inner parts of the housing should be wiped out with hot rinsing water when replacing the filters. Note:

When cleaning the inside of the housing avoid protruding parts.

Fig. 14

After having cleaned them, re-insert the grease filters in the hood in reverse order.

Important:

The handles of the grease filters must be visible after assembly.

Press the F key to set the elapsed hours counter to zero. Flashing of the indicating lamp goes off.

10

Image 10
Contents Page Preface Safety notes Read And Save These Instructions For your safety Important notesOperating for the first time About useFeatures Operation Page Special functions Cleaning and care Page Maintenance Assembly instructions Technical dataInstallation Condensate separator RV 060-150 must be installed Important Before marking the securing holes Page Operating and assembly instructions Extractor hood