file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm
TECHNICAL SPECIFICATION
INSTALLER SERVICING INSTRUCTIONS - GC3 (THREE OVEN)
YEARLY SERVICE
INSTALLATION
NOTE: THESE INSTRUCTIONS SHOULD BE LEFT WITH THE APPLIANCE AND THE USER TO RETAIN FOR FUTURE REFERENCE.
Aga Gas Fired ranges are delivered unassembled.
Before installation can be made the site is inspected for suitability by an Authorised Aga Distributor and corrected where necessary to conform with local installation codes or in the absence of local codes with:
In Canada:
The
In U.S.:
The National Fuel Gas Code NASI Z223.
Assembly is undertaken on site by the same Aga Distributor to ensure correct performance and safety.
BASE OR HEARTH
It is essential that the base or hearth on which the range stands should be level and strong enough to support the total weight of the range.
Approximate weight:-
Model GC3 (Open Flue) - 477 kg (1049 lb)
The top face of the hearth must be of
OPEN FLUE RANGE - MODEL GC3 (THREE OVEN)
The wall behind the cooker draft hood and flue connector must have a minimum air gap of 57mm (2 1/4"). Any openings in the wall behind the range or in the floor under the range must be sealed before appliance installation.
Ensure the draft hood is securely bolted to the support spigot as shown in Fig. 2.
NOTE: THIS IS NORMALLY FITTED AND SECURED BY THE FACTORY BEFORE DESPATCH.
The wall behind the range must be the outside wall for the venting of flue products.
Recommended amount of
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm (2 of 11)8/17/2006 10:51:16 AM