file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm
Fig. 4 - Model GC3 Open Flue DESN 512430
LOCATION OF NAME PLATE
The model and serial numbers for this appliance are found on the data plate. These numbers must be used when requesting advice from your Aga Distributor. The name plate is located on the burner housing panel behind top left door. The maximum gas inlet pressure at the appliance must not exceed 12 inches w.g. (2.98kPa) for Natural Gas and 14 inches w.g. (3.48kPa) for L.P. Gas. The minimum gas inlet pressure at the appliance must be 4 inches w.g. (1kPa) Natural Gas and 10 inches w.g. (2.248kPa) L. P. Gas to enable the correct manifold pressure to be obtained.
INITIAL LIGHTING OF RANGE
In a cold range, difficulty may be experienced in maintaining the main burner alight on initial
the control knob to theposition. Depress knob and light pilot. With the pilot flame established, rotate the gas valve control knob 2