Fig 3.

WALL TILING

If the cooker is to stand in a recess or against a wall which is to be tiled in no circumstances should the tiles overlap the range top plate.

GAS SUPPLY - U.S. PIPE THREADS

NOTE: A GAS CONTROL VALVE MUST BE INSTALLED IN THE GAS PIPELINE EXTERNALLY OF THE RANGE (NOT SUPPLIED).

9.5mm (3/8in) N.P.T. Male connection near the front of the range on the LH or RH side. (Optional).

ALL GAS CONTROLS MUST BE U.S. PIPE THREADS.

Maximum Heat Input: 4.4kW (15,000 Btu/h).

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure in excess of 1/2 psig (3.5kPa). The appliance must be isolated from the gas supply piping system by closing the individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa).

APPLIANCE DIMENSIONS

file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm (5 of 11)8/17/2006 10:51:16 AM

Image 5
Contents Installation Instructions Open Flue Range Model GC3 Three Oven InstallationBase or Hearth Vent Connection Canada GAS Supply U.S. Pipe Threads Appliance DimensionsWall Tiling Initial Lighting of Range Location of Name PlateBaking Oven Baffle Plate Replacement PartsDesn Yearly Service Installer Servicing Instructions GC3 Three OvenPage Woodcrest Road Cherry Hill 800.633.9200