QSC Audio CM16a manual Connecting to the RS-232 Port, Connecting to 2-CHANNEL Amplifiers

Page 21

Section 2: Installation- Connections

CONNECTION TO 10BASE-T (network connection)

Connection to the Ethernet network is made using the RJ-45 type connector labeled 10BASE-Ton the rear panel.“RJ-45” is the standard network connector for Ethernet networks. Insert the RJ- 45 plug into the receptacle with the lock-tab oriented toward the bottom of the CM16a and push firmly until the connector locks into place (usually an audible “click” can be heard). Refer to Section 1 of this manual for Ethernet connection schemes and cabling. If the CM16a is connected directly to the system control- ler computer’s network interface card, a crossover type cable is required. All other connection methods utilize normal Ethernet cabling.

CONNECTING TO THE RS-232 PORT

Connection is made with a null-modem serial cable with a DB-9 male plug to the CM16a. The RS-232port can be used for setting various operational parameters that are CRITICAL to proper operation of the CM16a. The network address settings can be changed through this port. Do Not Change the Network

Address unless you are certain of what you are doing!

Refer to Section 3 (page 27) for more information.

CONNECTING TO 2-CHANNEL AMPLIFIERS

2-channel amplifiers require a cable connection from the amp’s DataPort to the appropriate PORT receptacle on the CM16a. These HD-15 type connectors are labeled PORT A through PORT H. Use standard 15 pin VGA monitor cables (the same type of cable that interconnects PC’s & monitors).

To connect the cable to the CM16a, orient the HD-15 connector with its wider-side down (look at the connector, one side of the plug’s metal surrounding is wider than the other) and align it with the receptacle, then gently push into the receptacle until it is firmly seated. Use the retaining screws on the cable ends to secure the plug to the CM16a and the amplifer. Tighten “finger tight” to avoid damage to the HD-15 receptacle. The same basic procedure applies for connecting the other end of the cable to the amplifier’s DataPort.

CONNECTING TO 4-CHANNEL AMPLIFIERS

Two basic rules must be adhered to:

First, both DataPorts of the amplifier must be used.

Second, both must be connected to the same CM16a.

If only one DataPort connection is used, the CM16a will not control or monitor the amplifier correctly (the same applies for connecting the two amplifier DataPorts to two separate CM16a’s; the system will not function properly). Insure that both amplifier DataPorts are used and that they are connected to the same CM16a. You do not have to use adjacent ports on the CM16a (i.e. PORT C and PORT D). You can use any two ports for convenience; the only impact of doing this is that the System Manager software control panel will not show all four channels next to each other.

21

Image 21 Contents
CM16a Amplifier Network Monitor ¨ Warning ¨ Table of Contents CM16a Amplifier Network Monitor Federal Communications Commission FCC Information Series are not supported by the CM16a Introduction- OverviewPhysical Characteristics Introduction- Physical Characteristics & LayoutRS-232 port for network and firmware utilities Introduction- Physical Layout DiagramFunctional LISTING, Block Diagram & Detailed Descriptions Introduction- List of Functions & FeaturesIntroduction- Block Diagram part Introduction- Block Diagram part Introduction- Detailed Description of Functions Amplifier Monitoring Functions Introduction- Detailed Description of FunctionsRS-232 Port Functions Introduction- Network Description Introduction- Sample Network Topologies Introduction- Sample Network Topologies What is Included in the Carton Installation- Basics and Mounting Unpacking Location ConsiderationsConnecting AC Power Installation- Mounting and AC PowerConnecting Audio Inputs Installation- ConnectionsConnecting the RLY/TRG Connecting page InputConnecting the RLY OUT Connecting the Monitor Chain IN/OUTConnecting to the RS-232 Port Connecting to 2-CHANNEL AmplifiersConnecting to 4-CHANNEL Amplifiers Installation- Rear Panel Detail Port Connected LED’s Operation- LED IndicatorsSTART-UP Behavior and Preset Operating Operation- General Information & PresetsMost up-to-date information Operation- Recalling Presets Using RLY/TRGOperation- Bypass Modes and Switch Location HOW to put the CM16a into Bypass Mode #1HOW to put the CM16a into Bypass Mode #2 Operation- Serial Port I/O Interface RS-232 Communications ProcedureXon/Xoff Only Required for Attaching to Existing Networks IP Address AssignmentThis is the basic procedure for opening a Telnet session Operation- Telnet AccessFuse Replacement Operation- Fuse ReplacementSpecifications- Dimensions Specifications Input Signal ProcessingPower amplifier output processing Power amplifier management Control room foldback monitoringContact closure inputs and outputs General RS232 PortARCHITECT’S and ENGINEER’S Specifications Ethernet Cabling Appendix- Ethernet Cable PinoutsAppendix- DataPort Pin-out & Connector P-N’s Pin Signal DescriptionRS-232 Pinout How to Contact QSC Audio Products