PRODUCT DATA SHEETS
Standard Interior Water Filtration System Model
Tested and certified by NSF International against ANSI/NSF
Standard 42 for the reduction of Chlorine (Class I), Taste and Odor.
Capacity : 200 gallons (757 liters),
Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance | U.S. EPA | Average | Maximum | Average | Minimum % | Average % | NSF Test |
Reduction | MCL | Influent | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
Chlorine, Taste/Odor | N/A | 2.0 mg/L | N/A | 0.02 mg/L | N/A | 99% | 994715 |
Cyst Interior Water Filtration System Model
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity: 200 gallons (757 liters),
Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance Reduction | U.S. EPA | Average | Maximum | Average | Minimum % | Average % | NSF Test |
Aesthetic Effects | MCL | Influent | Effluent | Effluent | Reduction | Reduction | Number |
Chlorine Taste/Odor | N/A | 1.9 mg/L | N/A | 0.06 mg/L | N/A | 97% | 994707 |
Particulate | N/A | 108,667/mL* | N/A | 45/mL | N/A | 99.96% | 994711 |
|
|
|
|
|
|
|
|
Contaminant | U.S. EPA | Average | Maximum | Average | Minimum % | Average % | NSF Test |
Reduction | MCL | Influent | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
Cyst | 99.95%** | 157,750/mL | 55/mL | 1.0/mL | 99.9987% | 99.9996% | 994710 |
Turbidity | N/A | 26 NTU | 0.5 NTU | 0.1 NTU | 98.9% | 99.5% | 994710 |
|
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.015 mg/L | 0.160 mg/L*** | 0.011 mg/L | 0.001 mg/L | 93.5% | 99.4% | 994708 |
Lead: @ pH 8.5 | 0.015 mg/L | 0.158 mg/L*** | 0.011 mg/L | 0.001 mg/L | 92.1% | 99.3% | 994709 |
|
|
|
|
|
|
|
|
■It is essential that operational, maintenance, and filter replacement requirements be carried out for this product to perform as advertised.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
■Model NL200 Change cartridge at least every
■Model NLC200 Change the cartridge at least every
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
■Refer to the “Assistance or Service” section for the Manufacturer’s name, address and telephone number.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8° C) |
*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53.
***Test requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
®NSF is a registered trademark of NSF International.
23