EN
Specifications
Frequency Response1: |
|
|
85- 20k Hz | 63- 20k Hz | |
Maximum Output2: | 102 dB SPL continuous rms output | 103.5 dB SPL continuous rms output |
(calculated) | 108 dB SPL peak output | 109.5 dB SPL peak output |
Transducers: | LF: 133 mm (5.25”), 25 mm (1”) voice coil; | LF: 133 mm (5.25”), 25mm (1”) voice coil; |
| weatherproof, | weatherproof, |
| HF: 25mm (1”) titanium dome, neodymium | HF: 25mm (1”) titanium dome, neodymium |
| magnet. | magnet. |
Nominal Coverage: | 90° conical (average 1 kHz - 4 kHz) | 100° conical (average 1 kHz - 4 kHz) |
Impedance (ohms): | 8.0 nom./ 6.4 min. @ 15 kHz. | 8.0 nom./ 6.0 min. @ 13 kHz. |
Power Rating3: |
|
|
rms (IEC 100 hrs): | 40 watts rms (30 watts, | 40 watts rms (30 watts, |
recommended amp power: | 80 watts rms, maximum | 80 watts rms, maximum |
Sensitivity: | 86.0 dB, 1 watt, 1 meter, flush mounted (2 pi) | 87.5 dB, 1 watt, 1 meter, flush mounted (2 pi) |
Bass Loading: | sealed | ported, tuned to 75 Hz. |
Optional Processing: | 65 to 125 Hz. high pass >12 dB/octave | 55 to 125 Hz. high pass >12 dB/octave |
Dimensions: | see drawings | see drawings |
Net Weight: | ||
Enclosure: | ||
Mounting System: | Captive, integral mounting clamps. Insert enclosure into cutout, and tighten. Suspended ceiling | |
| and support bars included. |
|
Connectors: | Terminal block connector inputs and terminal block “through” connectors (rated for 400W max). | |
Controls: | Transformer “tap” selector/ bypass (8 ohm) switch, settings: 3.75, 7.5, 15, and 30 watts (7.5, 15, 30 watts | |
| for 100V) and 8 ohms. 70/100V Insertion loss: 0.8 dB, Averaged over 50Hz - 20kHz bandwidth (30W tap). | |
| Transformer Distortion: less than .01% THD above 100Hz, 0.2% @ 50Hz (30W tap). Bandwidth: 40 - 20k | |
| Hz |
|
Agency Listings: CE, UL 1480 (commercial/professional use, outdoor damp), UL 2043 (air handling spaces).
Specification Notes:
1- All frequency ranges specified refer to measured
2- Calculated maximum peak SPL at 1 m,
3- Maximum input power tested in accordance with IEC recommendations; 50 Hz to 20 kHz band limiting, 6 dB signal crest factor.
Specifications are subject to change without notice.
For detailed information, visit QSC’s web site at http://www.qscaudio.com or call us at
6