INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools needed
■Adjustable wrench or ⁵⁄₈" wrench
■Phillips screwdriver
■
■Measuring tape
■Hand or electric drill (for wall cabinet installations)
■1" (25 mm) drill bit (for wall cabinet installations)
■Level
■Copper tubing cutter
Parts supplied (1 box, 3 plastic bags)
■One - ³⁄₈" stem to ¹⁄₄" quick connect
■Two - ³⁄₈" elbow to ¹⁄₄" quick connects
■Water filter
■
■
■Bottom vent (supplied on some models)
■
Parts needed
■UL listed or CSA approved conduit connector
■UL listed wire connectors
■Tubing staples/retainers
■¼" O.D. copper tubing (to make water connection)
NOTE: Due to temperatures around oven, copper tubing is required.
■Water connection device (to connect ¼" O.D. copper tubing to water source). Check local codes for type of connection required.
■¼" to ¼" water supply union (between copper tubing from the filter and copper tubing attached to oven)
Built-In Microwave/Oven Combination
Location Requirements
Make sure you have everything needed for correct installation.
IMPORTANT: Observe all governing codes and ordinances.
■Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance with oven.
■Recessed installation area must provide complete enclosure around the recessed portion of the oven.
■Grounded electrical supply is required. See “Electrical Requirements” section.
■Electrical supply junction box should be located 3" (7.6 cm) maximum below the support surface when the oven is installed in a wall cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the right rear or left rear corner of the support surface to pass the appliance cable through to the junction box.
■Oven support surface must be solid, level and flush with bottom of cabinet cutout. Floor must be able to support a total weight (microwave and
Product Dimensions
A
B
E
Check local codes. Check existing electrical supply. See “Electrical Requirements.”
D
C
It is recommended that all electrical connections be made by a licensed, qualified electrical installer.
A. 28⁵⁄₁₆" (71.9 cm) recessed width
B. 42⁵⁄₁₆" (107.5 cm) overall height
C. 29³⁄₄" (75.6 cm) overall width
D. 23" (58.4 cm) max. recessed depth
E. 40³⁄₄" (103.5 cm) recessed height
2