Broan P408ICAT Remove Filters and Grease Drip Rail, Remove the Adapter Internal Blower Hoods only

Page 8

4. REMOVE FILTERS AND GREASE DRIP RAIL

A.Remove tape on filters.

Remove filters from hood and set aside.

NOTE: It is recommended to start with the center one(s).

B.Remove tape on grease drip rail (1). Lift out grease drip rail and set aside.

 

1

A

B

HD0240

 

5.REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)

SINGLE BLOWER HOOD

Remove both screws retaining the adapter/damper (1) from inner top of the hood.

DOUBLE BLOWER HOOD

First unplug both blower motors (1) before removing 3 screws retaining the adapter (2) from inner top of the hood.

Fold the adapter and insert the male part (grey section shown in inset) into the female part (white section shown in the inset). Then, fold over each male and female end to finalize assembling the adapter.

1

HD0259

1

2

HD0283

HD0284

- 8 -

Image 8
Contents Installation Instructions Intended for Domestic Cooking onlyTo Reduce the Risk of a Range TOP Grease Fire E64000 Series Range Hood System Internal Blowers E64000 Series Range Hood System IN-LINE and Exterior Blowers Select Blower Option and Installation Type Prepare the Installation Prepare the Installation CONT’D Install Backsplash OptionalRemove Filters and Grease Drip Rail Remove the Adapter Internal Blower Hoods onlyHorizontal Discharge Installation Internal Blowers only Choose the Openings Internal Blower Hoods onlyInstall the Adapter and the Transition if Need be Internal Blower Hood onlyInstall the Blower Exterior or IN-LINE Blower Hood Install the Hood ALL BlowersConnect Wiring ALL Blowers Install Light Bulbs Reinstall Grease Drip Rail and FiltersUSE and Care OperationWarranty Operation CONT’DWiring Diagrams Internal blower hoodsService Parts Broan Elite E64000 Series Exterior or In-Line blower hoods