Broan QTRE100S warranty Typical Installations, Plan the Installation Install Housing & Duct

Page 2

MODEL QTRE100S

Page 

TYPICAL INSTALLATIONS

Housing mounted to

Housing mounted anywhere between

I-joists.

I-joists using hanger bars.

Locate unit above (GFCI protected circuit required) or within 5 feet of shower head.

Locate unit away from heating or cooling sources which can affect humidity levels.

Do not locate near window. Unit may respond to the outdoor humidity level.

Unit must be installed in ceiling to properly sense moisture.

Locate unit only on flat ceilings up to 12 feet high for proper sensing.

The fan will operate most efficiently when located where the shortest possible duct run and minimum number of elbows will be needed.

Use a roof cap or wall cap that has a built-in damper to reduce backdrafts.

2.Plan the wiring.

Plan to supply the unit with proper line voltage and appropriate power cable. Power cable should be routed to the switch box first and then to the unit (See “CONNECT WIRING” on page 3).

Do not operate this unit with a speed control. Damage to the sensor unit will result.

Housing mounted to joists. Housing mounted anywhere between joists using hanger bars.

Housing mounted anywhere be-

Housing mounted anywhere be-

tween trusses using hanger bars.

tween trusses using hanger bars.

PLAN THE INSTALLATION

INSTALL HOUSING & DUCT

1a.Mount housing to joist or I-joist.

Use a pliers to

 

bend housing

TABS

TABS out to

 

900. Hold hous-

 

ing in place so

 

that the hous-

 

ing tabs con-

 

SPACER

tact the bottom

1.Choose the installation location.

The location of your humidity sensing fan is very important. Use the follow- ing guidelines for best opera- tion:

insulation

 

 

(Can be placed

 

 

around and over fan

 

ROOF

housing.)

 

CAP *

fan

 

 

 

housing

4-in.

 

 

 

ROUND

 

 

* Purchase

DUCT *

4-in. ROUND

WALL

separately

 

ELBOW(S) *

CAP *

of the joist .

(use for mounting to I-Joist)

The housing

 

mounts with

 

four (4) screws

 

or nails. Screw

 

or nail housing

 

to joist through

 

lowest holes in

 

each mount-

 

i n g f l a n g e ,

I-JOIST

then through

highest holes.

 

NOTE: Mounting to I-JOIST(shown) requires use of SPACERS (included) between the highest hole of each mounting flange and the I-joist.

OR

Image 2
Contents Operation Cleaning & MaintenanceRead and Save These Instructions Plan the wiring Typical InstallationsPlan the Installation Install Housing & Duct 1a.Mount housing to joist or I-joistInstall Inch round duc Twork Connect WiringAttach damper/ duct connector Connect electrical wiringAttach grille to housing Install Grille Service PartsWarranty Finish ceilingPrecaución LEA Y Conserve Estas InstruccionesAdvertencia OperaciónPlanifique la conexión eléctrica Instalaciones TípicasInstale LA Cubierta Y EL Conducto 1a.Instale la cubierta en las viguetas o viguetasRedondo de 10,2 Cm 4 pulg Conexión EléctricaInstale el conducto Conecte los cables eléctricosTermine el cielo raso Instale LA Rejilla Piezas DE RepuestoGarantía Acople la rejilla a la cubierta