Broan QTRE100S Connect Wiring, Attach damper/ duct connector, Install Inch round duc Twork

Page 3

MODEL QTRE100S

Page 

1b.Mount housing anywhere between trusses, joists, or I-joists using hanger bars.

Sliding hanger bars are provided to allow for accurate posi- tioning of housing anywhere between framing. They can be used on all types of framing (I-joist, standard joist, and truss construction) and span up to 24”.

 

tab

 

screws (4)

hanger

mounting

channel (2)

bar (4)

 

Attach the MOUNTING CHANNELS to the housing using the screws supplied. Make sure TABS face “up” as shown. Use the set of channel mounting holes (marked “STD”) to mount the housing flush with the bottom of the drywall. Use the other set of holes (not marked) to mount the housing flush with the top of the drywall.

hole for optional

*

screw (2)

screw mounting (4)

 

 

 

2. Attach damper/ duct connector.

Snap damper / duct con- nector onto housing. Make sure connector is flush with top of housing and damper flap falls closed.

3.Install

4-inch round duc-

twork.

Connect 4-inch round ductwork to damper / duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork con- nections to make them secure and air tight.

CONNECT WIRING

WIRING OPTION #1 - Allows fan to operate in automatic mode or manual mode (for odor control) by cycling ON/OFF switch.

ON / OFF SWITCH

(PURCHASE SEPARATELY)

 

ORG

BLK

FAN

WHT

ON / OFF

 

 

 

 

 

 

 

SWITCH

 

 

 

 

BLK

BRN

HUMIDITY

WHT

 

 

 

CONTROL

 

BLK

 

 

 

 

 

 

 

120

WHT

WHT

WHT

VAC

LINE

GRD

GRD

 

IN

 

 

SWITCH BOX

 

UNIT

WIRING OPTION #2 - Fan can be turned ON, OFF, or set to operate automatically.

MODEL 68W, 2-FUNCTION CONTROL

(PURCHASE SEPARATELY)

 

bottom edge

nail (4)

of framing

Extend hanger bars to the width of the framing.

Hold ventilator in place with the hanger bar tabs wrapping around the bottom edge of the framing.

Nail ventilator to framing or fasten with screws (not provided) through holes near nails.

 

 

FAN

RED

ORG

 

 

 

 

 

 

(ON/OFF)

 

 

 

 

 

COM

 

 

 

HUMIDITY

BLK

BRN

 

 

CONTROL

 

 

 

(AUTO/OFF)

 

 

120

 

BLK

 

 

 

 

WHT

 

VAC WHT

 

LINE

GRD

GRD

 

IN

 

 

 

 

 

 

SWITCH BOX

BLK

FAN

WHT

 

 

HUMIDITY

WHT

 

CONTROL

 

 

 

WHT

UNIT

*To ensure a noise-free mount: Secure hanger bars together with screws or use a pliers to crimp mounting channels tightly around hanger bars.

4. Connect electrical wiring.

Run 120 VAC house wiring to installation location. Use proper UL approved connector to secure house wiring to wiring plate. Connect wires as shown in wiring diagrams.

Image 3
Contents Cleaning & Maintenance Read and Save These InstructionsOperation 1a.Mount housing to joist or I-joist Typical InstallationsPlan the Installation Install Housing & Duct Plan the wiringConnect electrical wiring Connect WiringAttach damper/ duct connector Install Inch round duc TworkFinish ceiling Install Grille Service PartsWarranty Attach grille to housingOperación LEA Y Conserve Estas InstruccionesAdvertencia Precaución1a.Instale la cubierta en las viguetas o viguetas Instalaciones TípicasInstale LA Cubierta Y EL Conducto Planifique la conexión eléctricaConecte los cables eléctricos Conexión EléctricaInstale el conducto Redondo de 10,2 Cm 4 pulgAcople la rejilla a la cubierta Instale LA Rejilla Piezas DE RepuestoGarantía Termine el cielo raso