5. CHOOSE THE OPENING (INTERIOR BLOWER)

Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate). See pictures below.

CAUTION

When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the knockout corresponding to the ducting installed (10’’ or 14’’).

14’’ KNOCKOUT

10’’ KNOCKOUT

HD0076

Removing horizontal knockout opening on back of hood

14’’

KNOCKOUT

 

10’’

KNOCKOUT

 

 

 

 

 

 

HD0077

Removing vertical knockout opening on rough-in plate

6. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)

INTERIOR BLOWER: Secure the rough-in plate (provided with the P5 and P8 blower) inside the hood with four (4) lock nuts. See picture below.

HD0042

EXTERIOR OR IN-LINE BLOWER: Purchase Model 332KR separately. Refer to instructions included with the rough-in kit. Secure the rough-in plate inside the hood with (4) lock nuts.

7. INSTALL THE DEVIATOR (INTERIOR BLOWER)

YOU MUST install the deviator if you choose to vent the hood vertically.

Install the deviator as shown.

NOTE: If installed correctly, the deviator will protrude about 1/8” above the rough-in plate.

HD0003

- 7 -

Inserting deviator into hood vertical opening

Image 7
Contents Series This unit must be grounded Series Range Hood System Interior Blowers Series Range Hood System IN-LINE and Exterior Blowers Select Blower Option and Install Ductwork Install Backsplash Optional Prepare the InstallationSelect Blower Option Exterior or Interior Install the Deviator Interior Blower Install the ROUGH-IN Plate ALL BlowersChoose the Opening Interior Blower Install the Hood ALL Blowers Install the Adapter Interior BlowerInstall the Blower Interior Blower Connect Wiring ALL BlowersDual blower P8 Install the Blower Interior Blower CONT’DUSE and Care Install FiltersLight Bulbs Heat LampsOperation USE and Care CONT’DNever place highly flammable material under warming lamps Operation CONT’DSeries Service PartsSingle BLOWER/ROUGH-IN Model P5 Dual BLOWER/ROUGH-IN