PREPARING THE HOOD
1.Unpack hood and check contents. You should receive: 1 – Filter with
1 –
1 – Installation parts bag
LIGHT LENS
ALUMINUM OR
COMBINATION
FILTER
2. Remove junction box cover. | JUNCTION BOX |
|
3.Remove top or rear electrical knockout.
4.Select one of the three types of venting available:
VENT COVER
②①
③
Rectangular Vented —
ROOF CAP
ROOF CAP
BP87 DAMPER (NOT IN-
CLUDED) LOCATED AT
LEAST 6" FROM HOOD
IN VERTICAL SECTION
OF DUCT
DAMPER (INCLUDED)
REMOVE THE
HOOD DAMPER
FLAP IF IT IN-
TERFERES WITH
THE WALL CAP
DAMPER
Ducting directly through the wall (for range hoods mounted on an exterior wall). Shown are two ways to duct through an outside wall. If a wall cap is used directly off the back of the hood, special care must be taken to make sure that the damper in the damper/duct connector on the hood and damper in the wall cap do not interfere with each other when the hood is operating. This could result in either inadequate air delivery or back drafts. If this condition does exist, remove the hood damper flap. Sometimes when using a wall cap, it is easier to duct vertically and then use an elbow.
Ducting straight up through roof using
Ducting between ceiling joists for
PREPARING THE INSTALLATION LOCATION
NOTE: MOUNT HOOD SO THAT BOTTOM OF HOOD IS 18" TO 25" ABOVE COOKING SURFACE. TOP FRONT OF HOOD SHOULD BE FLUSH WITH FRONT OF CABINET FRAME.
IF DISTANCE BETWEEN WALL AND FRONT OF CABINET FRAME IS MORE THAN 12", THERE WILL BE A SPACE BE- TWEEN BACK OF HOOD AND WALL. THIS IS NORMAL.
OMIT STEP 1 IF HOOD WILL BE INSTALLED UNDER CABI- NETS WITH FLUSH BOTTOM.
Round Vented — 7" vertical. Remove knockouts #① and #② exposing duct collar. Go to "Planning Ductwork Installation".
PLANNING DUCTWORK
INSTALLATION
This section for vented hoods only.
Begin planning ductwork by deciding where duct will run between |
|
hood and outside. For best performance, use shortest possible |
|
duct run and a minimum number of elbows. There are several |
|
choices. | 2 |
|
FILLER STRIP
1.For cabinets with recessed bottoms only: Install wood filler strips on each side of recessed area under cabinet. Use two 1" x 2" strips cut to length (use thicker strips if necessary). Fasten strips with wood screws about 3" in from each end.
2.Measure and mark the following:
a.) Electrical wiring opening in wall or cabinet.
b.) Duct opening in wall or cabinet (vented hoods only).