8. CLEANING THE FILTER

1.Switch off the amplifier power.

2.Pull the filter from the front panel as shown in the figure.

3.Clean the filter.

4.Fit the filter in place.

[Precautions] Make sure that the fan is turned off when removing the filter.

Filter

9. REMOVING THE HANDLE

1.Switch off the amplifier power.

2.Remove the handle cover.

3.Remove two screws holding the handle to the amplifier.

4.Remove the handle.

5.Install the supplied screws (M4x20).

6.Attach the handle cover to the unit.

Handle

Handle cover

Handle cover

9

Image 9
Contents Operating Instructions IP SeriesPower supply plug from the AC outlet Safety PrecautionsDamage May cause fire or electric shockParts inside the product are a risk When unplugging the power supply cord, be sureHandling Precautions FeaturesGeneral Description Can be reducedFront Panel Nomenclature and FunctionsRear panel Installation Connections Removing the Handle Cleaning the FilterBlock Diagram Installing AN Optional Matching Transformer LT-101Table for Protection Circuit Actions Appearance and DimensionsCooling Fan Speed Connection Terminal Specifications