12. TABLE FOR PROTECTION CIRCUIT ACTIONS
Symptom  | Action  | Indicator  | Remedy  | Reset  | 
Excessive current flow  | Current limiter operates  | Peak indicator lights.  | Remove overload.  | Automatically reset if 4  | 
due to overload  | when load resistance is  | 
  | 
  | (STEREO/PARALLEL) or  | 
  | under 2.5 (STEREO/  | 
  | 
  | 8 (BTL) load is  | 
  | PARALLEL) or 5  | 
  | 
  | connected.  | 
  | (BTL).  | 
  | 
  | 
  | 
Short circuit (under 0.5 )  | Current limiter operates.  | Protection circuit  | Check short circuit of  | Switch power off, connect  | 
  | Speaker loads cut by  | indicator lights.  | speakers and lines.  | correct load, and switch  | 
  | 
  | 
  | power on.  | |
  | output relay.  | 
  | 
  | 
  | 
Heat sink temperature rise  | Speaker loads cut by  | Protection circuit  | Check ventilation and  | Automatically reset if  | 
  | output relay.  | indicator lights.  | overload.  | temperature drops.  | 
Unusual DC voltage output  | Speaker loads cut by  | Protection circuit  | Contact your TOA  | Switch power off, then  | 
  | output relay.  | indicator lights.  | dealer.  | remove cause.  | 