Bogen PCM2000 manual Configuration TWO-WAY Talk Back Extended Paging System

Page 18

CONFIGURATION 8:

TWO-WAY TALK BACK EXTENDED PAGING SYSTEM

This configuration is essentially the same as the two-way paging system described previously on page 17.The main difference is the addition of a satellite assembly.

The required setup includes: PCMTIM - 2 PCMCPU - PCMTBM - 4 PCMZPM - 2 PCMPS2

Note: Talk Back is only available in High-Power Zones with 25/70V AC speakers.

The paging access output from the telephone system must support two-way communications.

INSTALLATION:

STEP 1: Assembling Master Modules PCMTIM to PCMCPU to PCMTBM and to PCMZPM

Follow the same procedure described previously on page 17, step 1.

Note: Do NOT connect the PCMPS2 (power supply) at this point.

STEP 2: Assembling Satellite Modules PCMCPU to PCMZPM

Follow the same procedure described previously on page 15, step 2.

STEP 3: Switch Settings

Set the TEL-INT-SEL DIP switches on the PCMTIM module to match the paging output access from the telephone system based on the type of telephone interface used. (See step 3 on page 5 if using Page Port Contact Closure; page 7 for Page Port VOX; page 9 for Loop Start Trunk; page 11 for Ground Start Trunk; or page 13 for Station Level/Centrex.)

Set the SYS-ID DIP switches on the master PCMCPU module to the OFF position (to the left).

Set the SYS-ID DIP switches on the first satellite PCMCPU module to the following configuration: switch 1 to the ON position (to the right), switches 2, 3, & 4 to the OFF position (to the left). See additional SYS-ID settings on page 38.

Set the RUN-PROGRAM switch on each PCMCPU to the RUN mode (up).

• Set the TALK BACK switches on the PCMZPM modules to the ON position (to the right) for all zones.

Set the OUTPUT switch on each PCMZPM module to the HI-PWR position (down).

STEP 4: Testing your System

Connect one PCMPS2 power supply to each PCMCPU module to either the power jack 12V DC input or wire it to the 12V DC screw terminals, observing polarity.

At this point all the power LEDs should be lit on each module.

Access the paging from the phone system and verify access tones (double beep).

At this point, the system should be functioning properly.

Disconnect Power Supply.

STEP 5: Connecting the Paging Amplifier

Locate the terminals on the PCMTBM module labeled PA OUT/RT and wire to the COMMON and either 25 or 70V output on the Bogen paging amplifier (either TPU-Series, GS-Series or Classic Series).

Locate the terminals on the PCMTBM module labeled PA IN/RT and wire to the TIP and RING input on the Bogen paging amplifier.

STEP 6: Connecting 25/70V AC Speakers

Follow the same procedure described previously on page 5, step 6.

STEP 7: Testing your System

Connect a PCMPS2 power supply to each PCMCPU module to either the power jack 12V DC input or wire it to the 12V DC screw terminals observing polarity.

Connect the Bogen amplifier to the AC power outlet (120V AC 60Hz).

Set the volume on your Bogen amplifier to a 1/2 turn.

Access the paging from the telephone system and listen (on the handset) for the confirmation tone (double beep).

Dial 01 to access ZONE ONE and listen (on the handset and also to the speakers) for a pre-announce tone (single beep). At this point, you should be able to hear audio from the location where the speaker for ZONE ONE is installed.

The volume and delay controls on the PCMTBM module, control the audio back into the handset. Adjust these controls for best opera- tion.

Set the Bogen amplifier to the desired volume level.

19

Image 18
Contents PCM2000 Configuration Guide Contents Section I Setup for Configuration Testing your System InstallationSwitch Settings Connecting the Paging AmplifierPBX Assembling Modules Pcmtim to Pcmcpu and to Pcmzpm Loop Start Installation Ground Red and green Station Access Installation Satellite Assembly #1 Configuration Extended Paging System Assembling Master Modules Pcmtim to Pcmcpu and to PcmzpmBogen Configuration TWO-WAY Talk Back Paging System Connecting Telephone System Paging Output to the PcmtimSatellite Assembly #1 Configuration TWO-WAY Talk Back Extended Paging System Assembling Satellite Modules Pcmcpu to PcmzpmZone C Connecting the Paging Amplifiers Connecting Self-Amplified SpeakersAssembling Modules Setup for Configuration 10 6 25/70V Switch and Control Settings Connecting AmplifiersVAR1 Configuration Microphone Override Assembling Modules and Connecting the AmplifierConnecting Optional Equipment TAM B Connecting the Tamb Module to the DFT120 Connecting the DFT120 to the Pcmtim ModuleProhold Configuration Emergency Voice Announcement Override Shure Configuration Dtmf Microphone Zone Paging OperationTesting the System Connecting the BGM SourcePcmcpu Switch Settings Prepare System for OperationConfiguration Relay Driver Output Relay Power Supply 12VDCRemember to press the # key after you enter a Feature Code System ProgrammingFeature Codes and Defaults EM/SCClock Set Clock SyncTime Trigger Reset Default Setup Tone in Program Mode OnlyAppendix Zone #’s Master SatelliteSpring Street, Ramsey, NJ 07446 U.S.A
Related manuals
Manual 2 pages 49.44 Kb

PCM2000 specifications

The Bogen PCM2000 is a powerful and versatile public address (PA) system designed to deliver high-quality sound in a range of environments. Whether being used in schools, offices, retail spaces, or large auditoriums, the PCM2000 is engineered to meet diverse audio requirements while ensuring user-friendly operation.

One of the standout features of the PCM2000 is its modular design. This allows users to customize the system to fit their specific needs by adding or removing components. The system is built around a multi-channel amplifier, providing flexibility in configuring the sound output. The PCM2000 supports a range of audio sources, including microphones, CD players, and other auxiliary devices, making it adaptable for various applications.

The PCM2000 incorporates advanced digital signal processing (DSP) technology, which enhances overall audio quality. This technology enables features such as equalization, compression, and limiting, ensuring that the sound is clear and consistent across different environments. The system's DSP capabilities also help to minimize feedback and distortion, providing a professional-grade audio experience.

Another significant characteristic of the Bogen PCM2000 is its user-friendly interface. It features a simplified control panel that allows for intuitive operation. Users can easily adjust volume levels, select input sources, and manage other functionalities without extensive training. Additionally, the system can be integrated with existing networks, allowing for remote control and monitoring via a computer or mobile device.

The PCM2000 is highly reliable and built for long-term performance. It features a rugged construction designed to withstand the rigors of daily use, ensuring durability in commercial settings. Moreover, its efficient thermal management keeps the system cool during extended operation, reducing the risk of overheating and prolonging its lifespan.

The PCM2000 meets various safety and compliance standards, ensuring it is suitable for a wide array of installation environments. Its ability to interconnect with other systems, including fire alarms and emergency notification systems, makes it a critical component for comprehensive safety protocols.

In summary, the Bogen PCM2000 is an advanced public address system that combines modular design, sophisticated DSP technology, and user-friendly operation. Its reliability and versatility make it an excellent choice for any setting requiring clear and effective audio communication.