Bogen PCM2000 Installation, Switch Settings, Testing your System, Connecting the Paging Amplifier

Page 4

CONFIGURATION 1:

PAGE PORT CONTACT CLOSURE - 3-ZONE - ONE-WAY PAGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS

In this configuration, the PCM unit responds to a contact closure on pins 2 & 5 of the TEL LINE jack on the PCMTIM module shorting the +5V source to its ground.When the closure is removed, the page ends. Audio is provided to the system through a separate pair of leads on pins 3 & 4 of the TEL LINE jack on the PCMTIM module. Pins 1 & 6 are not used in this configuration.

Note:The audio pair (page port) must pass DTMF in order to select a zone.

The required setup includes PCMTIM - PCMCPU - PCMZPM - PCMPS2. Modules must be assembled, from left to right, in this order.

INSTALLATION:

STEP 1:Assembling Modules PCMTIM to PCMCPU and to PCMZPM (see Illustration on page 38)

Plug the 6-pin power connector from the PCMCPU module to the PCMTIM module jack (J2). Be sure that the locking ridge faces head- er wall. (Green wire to the top.)

Plug the 26-pin ribbon cable from the PCMCPU module to the PCMTIM module 26-pin connector (J1). Be sure to align the polarizing tab in slot. (Pin 1 red stripe to the top.)

Place the modules together and dress the connector cables away from the sheet metal so they will not get pinched.

Push the two units together while aligning the locking tabs in the PCMTIM module to the locking slots in the PCMCPU module. Slide the two units until the faces of both units are even.

Secure the two units together by tightening a screw into the screw clamp tab in the back of the PCMTIM.

Follow the same steps to add the PCMZPM module.

Note: Do NOT connect the PCMPS2 (power supply) at this point.

STEP 2: Connecting Paging Port/Contact Closure from the Telephone System to the PCMTIM Module

Take the page port audio pair from the telephone system and wire it to the RJ11 TEL-LINE jack to pins 3 & 4 (red and green); and the contact closure pair to pins 2 & 5 (black and yellow).

Use a 4- or 6-pin modular cord to connect the RJ11 to the TEL-LINE input on the PCMTIM module.

STEP 3: Switch Settings

Set the TEL-INT-SEL DIP switches on the PCMTIM module for Page Port Contact Closure configuration: switches 2, 3 & 7 ON (to the right) and switches 1, 4, 5 & 6 OFF (to the left).

Set the SYS-ID DIP switches on the PCMCPU module to the OFF position (to the left).

Set the RUN-PROGRAM switch on the PCMCPU module to the RUN mode (up).

• Set the Talk Back DIP switches on the PCMZPM module to the OFF position (to the left) for all zones.

Set the OUTPUT switch on the PCMZPM module to the HI-PWR position (down).

STEP 4: Testing your System

Connect power supply PCMPS2 to the PCMCPU module to either the power jack 12V DC input or wire it to the 12V DC screw ter- minals observing polarity.

At this point all the power LEDs should be lit on each module.

Access the page port from the phone system and verify access tones (double beep) in handset.

At this point, the system should be functioning properly.

Disconnect Power Supply.

STEP 5: Connecting the Paging Amplifier

Locate the terminals on the PCMCPU module labeled PA IN/RT and wire to the TIP and Ring (T & R) input on the Bogen paging amplifi- er (either TPU-Series, GS-Series or Classic Series.)

Locate the terminals on the PCMCPU module labeled PA OUT/RT and wire to COMMON and either the 25 or 70V output on the paging amplifier.

STEP 6: Connecting 25/70V AC Speakers

Locate the terminals on the PCMZPM module labeled ZONE A.These terminals have two connections marked + and -.Wire your speakers for ZONE ONE to these terminals. Observe polarity (-) to common (+) to selected tap setting.

Follow the same procedure for the terminals labeled ZONE B for ZONE TWO, and the terminals labeled ZONE C for ZONE THREE.

STEP 7: Testing your System

Connect the power supply PCMPS2 to the PCMCPU module to either the power jack 12V DC input or wire it to the 12V DC screw terminals, observing polarity.

Connect the Bogen amplifier to the AC power outlet (120V AC, 60Hz).

Set the volume on your Bogen amplifier to a 1/2 turn.

Access the paging from the telephone system and listen (on the handset) for the confirmation tone (double beep).

Dial 01 to access ZONE ONE and listen (on the handset and also to the speakers) for a pre-announce tone (single beep) followed by your page (audio).

Follow the same steps for ZONES TWO (02) and THREE (03).

Set the Bogen amplifier to the desired volume level.

5

Image 4
Contents PCM2000 Configuration Guide Contents Section I Setup for Configuration Installation Switch SettingsTesting your System Connecting the Paging AmplifierPBX Assembling Modules Pcmtim to Pcmcpu and to Pcmzpm Loop Start Installation Ground Red and green Station Access Installation Satellite Assembly #1 Configuration Extended Paging System Assembling Master Modules Pcmtim to Pcmcpu and to PcmzpmBogen Configuration TWO-WAY Talk Back Paging System Connecting Telephone System Paging Output to the PcmtimSatellite Assembly #1 Configuration TWO-WAY Talk Back Extended Paging System Assembling Satellite Modules Pcmcpu to PcmzpmZone C Connecting Self-Amplified Speakers Connecting the Paging AmplifiersAssembling Modules Setup for Configuration 10 6 25/70V Switch and Control Settings Connecting AmplifiersVAR1 Assembling Modules and Connecting the Amplifier Configuration Microphone OverrideConnecting Optional Equipment TAM B Connecting the Tamb Module to the DFT120 Connecting the DFT120 to the Pcmtim ModuleProhold Configuration Emergency Voice Announcement Override Shure Configuration Dtmf Microphone Zone Paging OperationConnecting the BGM Source Pcmcpu Switch SettingsTesting the System Prepare System for OperationConfiguration Relay Driver Output Relay Power Supply 12VDCRemember to press the # key after you enter a Feature Code System ProgrammingFeature Codes and Defaults EM/SCClock Sync Clock SetTime Trigger Reset Default Setup Tone in Program Mode OnlyAppendix Zone #’s Master SatelliteSpring Street, Ramsey, NJ 07446 U.S.A
Related manuals
Manual 2 pages 49.44 Kb

PCM2000 specifications

The Bogen PCM2000 is a powerful and versatile public address (PA) system designed to deliver high-quality sound in a range of environments. Whether being used in schools, offices, retail spaces, or large auditoriums, the PCM2000 is engineered to meet diverse audio requirements while ensuring user-friendly operation.

One of the standout features of the PCM2000 is its modular design. This allows users to customize the system to fit their specific needs by adding or removing components. The system is built around a multi-channel amplifier, providing flexibility in configuring the sound output. The PCM2000 supports a range of audio sources, including microphones, CD players, and other auxiliary devices, making it adaptable for various applications.

The PCM2000 incorporates advanced digital signal processing (DSP) technology, which enhances overall audio quality. This technology enables features such as equalization, compression, and limiting, ensuring that the sound is clear and consistent across different environments. The system's DSP capabilities also help to minimize feedback and distortion, providing a professional-grade audio experience.

Another significant characteristic of the Bogen PCM2000 is its user-friendly interface. It features a simplified control panel that allows for intuitive operation. Users can easily adjust volume levels, select input sources, and manage other functionalities without extensive training. Additionally, the system can be integrated with existing networks, allowing for remote control and monitoring via a computer or mobile device.

The PCM2000 is highly reliable and built for long-term performance. It features a rugged construction designed to withstand the rigors of daily use, ensuring durability in commercial settings. Moreover, its efficient thermal management keeps the system cool during extended operation, reducing the risk of overheating and prolonging its lifespan.

The PCM2000 meets various safety and compliance standards, ensuring it is suitable for a wide array of installation environments. Its ability to interconnect with other systems, including fire alarms and emergency notification systems, makes it a critical component for comprehensive safety protocols.

In summary, the Bogen PCM2000 is an advanced public address system that combines modular design, sophisticated DSP technology, and user-friendly operation. Its reliability and versatility make it an excellent choice for any setting requiring clear and effective audio communication.