Bertazzoni C36500X, C36600X, Z36600X manual Replacement Parts, Conversione to Different Types of GAS

Page 8

REPLACEMENT PARTS

Only authorized replacement parts may be used in performing service on the appliance. Replacement parts are available from factory authorized parts distributors.

CONVERSIONE TO DIFFERENT TYPES OF GAS

Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply. For Natural Gas fit regulator assembly described in Fig.

Adaptation of the pressure regulator for use with different type of gas

The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with Natural Gas at a nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is pre-arranged from the factory to operate with one of these gas/pressure as indicated in the pre-arranging labels affixed on the appliance, package and Instruction booklet.

To convert the regulator for use with the other gas different from which one it is pre-arranged it is enough perform the following operations:

1)Unscrew by hand the upper metal stopper of the regulator.

2)Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper, afterward screw it again in opposite way under the metal stopper (for gas reference see the written “LP” and “NAT” with relative indicating arrows on the white piece).

3)Screw again by hand the metal stopper in the original position on the regulator.

Operating in this way the gas regulator is converted for use with the other gas/pressure.

It is essential that the gasket and the pressure test point stopper are properly installed to avoid gas leakage

-CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:

To change the nozzles of the burners use the following procedure:

Lift up the burners and unscrew the nozzles ( Fig.) using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE shown below.

8

Image 8
Contents Bertazzoni Requirements Room ventilation Location and venting Backguard Installation Instruction Worktop Frontguard Installation InstructionsProximity to Side Cabinet Installation Cooker Hood Installation Electrical ConnectionPage GAS Connection Final PreparationReplacement Parts Conversione to Different Types of GASModels C36600X Z36 6 00 X C3Y0..U4X2 or 5A Control Panel Description Service & Maintenance InstructionsDescriptions Using Burners Manual ignitionCleaning the Appliance After Sale ServiceSpare Parts List Page