Bertazzoni C36500X, Z36600X, Z36500X manual Models C36600X Z36 6 00 X C3Y0..U4X2 or 5A

Page 9

Models C36600X (Z36 6 00 X) [C3Y0..U4X(2 or 5)A]

Adapting to different types of gas

Burner

Position

Injector

Gas

Pressure

Max Rate

Min Rate

By-pass

 

 

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

diam. [mm]

Auxiliary

Front R

0,90

NG

4”

3400

996

900

264

Regulated

 

 

0,54

LP (Propane)

11”

3400

996

900

264

0,29

Semi-Rapid

Rear L & C

1,18

NG

4”

6100

1787

1500

439

Regulated

 

Front C

0,70

LP (Propane)

11”

6100

1787

1500

439

0,36

Rapid

Rear L

1,55

NG

4”

10400

3047

2500

732

Regulated

 

 

0,92

LP (Propane)

11”

10400

3047

2500

732

0,47

Dual Burner

Front L Inner

0,80

NG

4”

2800

820

900

264

Regulated

 

0,49

LP (Propane)

11”

2800

820

900

264

0,29

 

Front L Outer

N°2 x 1,15

NG

4”

12000

3516

4500

1318

Regulated

 

 

N°2 x 0,70

LP (Propane)

11”

12000

3516

4500

1318

0,65

Models C36500X (Z36 5 00 X)

[C3W0..U4X(2 or 5)A]

 

 

Adapting to different types of gas

 

 

 

 

 

 

 

Burner

Position

Injector

Gas

Pressure

Max Rate

Min Rate

By-pass

 

 

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

 

[W]

Diam. [mm]

Auxiliary

Front R

0,90

NG

4”

3400

996

900

 

264

Regulated

 

 

0,54

LP (Propane)

11”

3400

996

900

 

264

0,29

Semi-Rapid

Rear L and R

1,18

NG

4”

6100

1787

1500

 

439

Regulated

 

 

0,70

LP (Propane)

11”

6100

1787

1500

 

439

0,36

Rapid

Rear L

1,55

NG

4”

10400

3047

2500

 

732

Regulated

 

 

0,92

LP (Propane)

11”

10400

3047

2500

 

732

0,47

Dual Burner

Centre Inner

0,80

NG

4”

2800

820

900

 

264

Regulated

 

0,49

LP (Propane)

11”

2800

820

900

 

264

0,29

 

Centre Outer

N°2 x 1,15

NG

4”

12000

3516

4500

 

1318

Regulated

 

 

N°2 x 0,70

LP (Propane)

11”

12000

3516

4500

 

1318

0,65

CAUTION: save the orifices removed from the appliance for future use

Regulation of burners

Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:

1)Light the burner and set the knob to the MINIMUM position (small flame).

2)Remove the knob of the valve that is press fit on the rod of that valve.

3)The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body and turn the choke screw to the right or left until the burner flame is adjusted to minimum

4)Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.

WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with liquid gas the screw must be locked at the end in a clockwise direction. The grill burner always operates at maximum and therefore no minimum adjustment is required.

9

Image 9
Contents Bertazzoni Requirements Room ventilation Location and venting Worktop Frontguard Installation Instructions Backguard Installation InstructionProximity to Side Cabinet Installation Electrical Connection Cooker Hood InstallationPage Final Preparation GAS ConnectionConversione to Different Types of GAS Replacement PartsModels C36600X Z36 6 00 X C3Y0..U4X2 or 5A Service & Maintenance Instructions DescriptionsControl Panel Description Manual ignition Using BurnersAfter Sale Service Cleaning the ApplianceSpare Parts List Page