Installation – Ductless Recirculating
www.zephyronline.com
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re- circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. The hood is most effective and efficient as an exhaust hood. Only when the exhaust option is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal filters are required on top of its standard Metal Filter set. Order according to its Part number below. The standard Metal Filters are intended to capture residue from cooking and the optional charcoal filters help to purify fumes exhausted from cooking for re- circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
Kit includes charcoal filters and air diverter plate.
Hood Model | Part No. | Filters in Pkg. |
| |
2 |
| |||
1. | Purchase recirculating kit per the part number above |
| ||
2. | Secure air diverter plate to wall below duct cover bracket. (FIG. B) |
| ||
| Run 6” ducting from top of hood and secure to air diverter plate. See |
| ||
| manual included with recirculating kit for more detailed instructions. | (blower | ||
|
|
|
| housing) |
3. | Remove metal mesh filters from hood. Clip charcoal filters onto each |
| ||
| charcoal filter bracket. (FIG. C) The brackets are |
| ||
| located beind the mesh filters. |
|
| |
4. |
|
| FIG. B | |
|
|
|
|
5. Enable charcoal filter change indicator on control panel. (Refer details to pg. 12)
6.Charcoal filters must be replaced after every 120 hours of use (or approximately every 3 to 4 months based on the average of 1 - 2 hrs. of daily cooking time). The microprocessor in the controls when set, will elapse and count usage time and indicate when charcoal filter replacement is required every 120 hrs.
Charcoal Filter Replacements
Hood Model | Part No. | Qty to Order |
|
| 2 |
front of the hood
E
D
DO NOT WASH CHARCOAL FILTERS. Charcoal filters may need to be changed more often depending on cooking habits.
Charcoal Filter Dimensions: 9in x 6 3/8in
228mm x 162mm
back of the hood
Install charcoal filter (plastic side exposed) into charcoal filter bracket. Insert tab
FIG. C