Zephyr ZMIM90AG Maintenance - Hood and Filter Cleaning, Surface Maintenance, Metal Mesh Filters

Page 16
Maintenance – Hood and Filter Cleaning

Maintenance – Hood and Filter Cleaning

www.zephyronline.com

SURFACE MAINTENANCE:

Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface.

For heavier soil use liquid degreaser.

After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.

Do not use any product containing chlorine bleach. Do not use “orange” cleaners.

Metal Mesh Filters

The metal mesh filters installed by the factory are intended to filter out residue and grease from cooking. They need not be replaced on a regular basis but are required to be kept clean.

After 30 hours of use the letter “A” will flash on the control screen indicating time to clean the metal mesh filters. Refer to instructions on page 13 on how to reset the indicator. Filters may need to be cleaned more depending on cooking habits.

Remove and clean by hand or in dishwasher on low heat. Spray degreasing detergent and leave to soak if heavily soiled.

Dry filters and re-install before using hood.

Removing Metal Mesh Filters

1.Push in on spring loaded handle

2.Pull down on filter hande to remove filter

Should filters wear out due to age and prolonged use, replace with following part number:

Hood Model:

Part No.

Qty to Order

ZMI-M90AS/AG

50200011

2

Metal Mesh Filter Dimensions:

10 1/8in. x 12 9/16in. 253mm x 314mm

14

Image 16
Contents Milano Wall Use, Care, and Installation GuideZMI-M90AS ZMI-M90AG Page Table of Contents INSTALLATIONFEATURES & CONTROLS MAINTENANCEImportant Safety Notice READ AND SAVE THESE INSTRUCTIONSOPERATION ELECTRICAL REQUIREMENTSList of Materials Ducting, conduit and all installation toolsCable connector if required by local codes Duct cover extension accessory - Z1C-00MIInstallation - Ducting Calculation Sheet Installation - Mounting Height & Clearance DUCTINGMinimum Mounting Height Ducted Maxmimum Mounting HeightInstallation - Ducting OptionsWARNING FIRE HAZARD w/ gravity damperInstallation - Hood Specificationsside of hood 20 1/2”Installation - Mounting the Hood fig. A fig. A2Cable Lock Cable LockInstallation - Ductless Recirculating Charcoal Filter ReplacementsRECIRCULATING KIT REQUIRED IF NO DUCTING IS USED FIG. CFeatures & Controls - Touch Controls Display speed level, delay off, filter clean/changeLights On/Dim/Off Adjust 6 Speed Levels 15 Min Delay Off Metal Filter Clean Reminder metal mesh filterChange Reminder Charcoal FilterFeatures & Controls Charcoal Filter Change Reminder charcoal filter, if installedFilter Clean Reminder Features & Controls - Metal MeshMetal Filter Clean Reminder metal mesh filter Metal Filter Clean IndicatorMaintenance - Hood and Filter Cleaning SURFACE MAINTENANCEMetal Mesh Filter Dimensions Metal Mesh FiltersMaintenance - Lights CAUTION Light bulb becomes extremely hot when turned onREPLACING LIGHT BULBS f theTroubleshooting TROUBLESHOOTING PROCEDURES FOR MILANO WALLIssue CauseList of Parts & Accessories Replacement PartsOptional Accessories DESCRIPTIONLimited Warranty JUN08.0101