the wall switch to both the red wire from the fan’s light receptacle and the black wire from the fan’s exhaust receptacle. Connect the ground wire from the house to the green wire from the fan’s grounding screw (Figure 10). Use approved methods for all connections.
Supply | Ground |
from |
|
house | White |
| |
| Hot (Black) |
Figure 10 | Hot (Red) |
4.Carefully tuck wire back inside wire compartment and replace wire compartment cover securing with the screw that was removed earlier.
SECTION 6
Completing the Installation
1.If the fan’s blower assembly was removed during the wiring process, reinstall the blower by reversing the directions in Step 1b in Section 5 Wiring.
2.Insert the fan’s plug into the receptacle (Figure 7).
3.Remove glass light lens from grill by unscrewing knob at the top of lens (Figure 11).
Glass Lens |
|
Figure 11 | Knob |
|
4.Plug cord from lamp holders into the appropriate receptacle (Figure 12).
| Cord |
| Lamp |
Figure 12 | Holders |
5.Line up slots in the grill with lances on inside of housing. Insert included #8 screws through grill slots and into housing lances. Tighten both screws until the grill fits snugly to the ceiling. DO NOT OVER TIGHTEN (Figure 13).
Lances
Grill
Figure 13 | #8 Screws |
CAUTION: FAILURE TO SECURE THE GRILL MAY RESULT IN A RATTLING OR HUMMING NOISE.
6.Install 2 - 60 watt maximum, type A19 medium base incandescent bulbs (not included).
7.Reinstall the glass lens in place by sliding the hole in the lens onto the rod from the grill and securing in place with the lens knob removed in step 3 (Figure 14).
Grill
Rod
Glass Lens |
| |
Hole | Knob | |
Figure 14 | ||
|
8. Restore power and test your installation.
SECTION 7
Use and Care
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT.
1.Cleaning the Grill: Refer to instructions in Section 6 Completing the Installation, to remove grill and glass light lens. Use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry all parts before reinstalling. Refer to instructions in Section 6 Completing the Installation, to reinstall grill and glass light lens.
2.Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER.
CAUTION: ALLOW BULB TO COOL BEFORE REPLACING.
210572200 Rev. A | www.airkinglimited.com | 4 of 12 |