Planning Information
60" (1524) Dual Fuel Ranges
M O D E L S D F 6 0 6 D G , D F 6 0 6 F, D F 6 0 6 C G , D F 6 0 4 C F A N D D F 6 0 4 G F
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.
IMPORTANT NOTE: Caution must be used in planning the proper installation of the Wolf dual fuel range to avoid any fires or damage to adjacent cabinetry or kitchen equipment. Be sure to follow minimum clearances established in the finished rough opening dimensions as shown in the illustration on page 4.
IMPORTANT NOTE: A minimum 10" (254) riser is required for all 60" (1524) dual fuel range models installed against a combustible surface.
A Wolf Pro ventilation hood or hood liner is recommended. When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to countertop. Also refer to the ventilation recommendation charts in the Pro ventilation section of our website, wolfappliance.com.
The 60" (1524) dual fuel range requires a 240/208 V AC, 60 Hz, 50 amp fused electrical supply to operate the electrical portions of the range. Locate electrical within the shaded area shown in the illustration on page 4.
Wolf dual fuel ranges are designed with a terminal block on the rear of the range. The terminal block allows for a
Wolf dual fuel ranges are designed to operate on natural gas at 5" (12.5 mb) WC (water column) pressure or LP gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14"
(34.9 mb) WC; .5 psi (3.5 kPa).
Wolf recommends the use of a 1/2" (13) I.D. commercial type flex hose; this is the minimum size that may be used. All plumbing to the flex hose must be 3/4" (19) minimum I.D. pipe.
IMPORTANT NOTE: A separate external gas
You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services.
Wolf dual fuel ranges using natural gas function up to an altitude of 8,000' (2438 m) without any adjustment. Natural gas and LP gas installations from 8,000' (2438 m) to 11,000' (3353 m) need the high altitude kit. Contact your Wolf dealer for details. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.
Refer to the installation instructions shipped with each Wolf product for detailed specifications.
Dimensions in parentheses are in
millimeters unless otherwise specified. | 5 |