Vermont Casting CF9080, CF9050 Natural Gas Supply Connection, Testing For Gas Leaks, To Connect

Page 11
Gas Hookup
Fig. 6a

Natural Gas Supply Connection

To Connect:

1.Push back the Sleeve on the Socket as shown below (see Fig. 6a).

2.Insert Plug and release the Sleeve (see Fig. 6b).

3. Push the Plug until Sleeve snaps forward to lock

Retract Sleev

e

the Plug in the Socket.

 

 

WARNING: Always conduct the following safety tests before lighting the Grill, to prevent a possible fire or explosion (see leak test below).

To Disconnect:

1. Push Sleeve back and pull the Plug out.

Testing For Gas Leaks

Before attempting to operate this Grill :

 

 

 

 

1. Always confirm that all burner control knobs are

R

elease Sleeve

 

Fig. 6b

in the OFF position.

 

 

 

 

 

 

 

 

 

 

 

2.Always connect the gas supply hose first and then open the gas shutoff valve.

3.Always use a brush or spray bottle to apply a 50/50 solution of liquid soap and water to all connection points (see Fig. 5) to test for gas leaks. Never use a match or open flame for that purpose.

4.Always look for bubbles to appear, as the appearance of bubbles will indicate a gas leak. Always turn off the gas immediately and tighten the connection, if you find that a leak exists.

5.Always repeat this procedure until no further gas leaks are found to exist, before lighting the Grill.

6.Never attempt to light this Grill, however, if a leak cannot be stopped. Always call your gas supplier promptly to obtain assistance.

WARNINGS:

Always consult the Rating Label on the back of the Grill to confirm that it has already been configured to burn Natural Gas. If it is necessary to reconfigure the Grill, however, always utilize the Natural Gas Fuel Conversion Kit available from

CFM Harris Systems Customer Service (800) 944-8982, to prevent possible bodily injury.

All gas suppy plumbing should be performed only by a qualified service agency. In the U.S., the supply connection must be made in accordance with local code or, in the absence of local codes, with the national fuel gas codes, ANSI Z223.1. In Canada, the supply connection shall be carried out in accordance with the provincial authorities having jurisdiction and in accordance with the requirements of the CAN/CGA 1-B149.1 AND .2 installation code. A shut-off value must be installed between the gas grill and the main supply. For natural gas, use a 3/8” or 1/2” natural gas supply line capable of an a input of at least 75,000 BTU’S.

Always disconnect the Grill and close its individual manual shutoff valve, when conducting pressure tests of the gas supply piping system at pressures which exceed 1/2 psi (3.5kPa).

Always isolate the Grill from the gas supply piping system by closing its individual manual shutoff valve when conducting pressure tests of the gas supply piping system at pressures which are equal to or less than 1/2 psi (3.5kPa).

Page 5

Image 11
Contents USER’S Manual For Your Safety Signal Words Safe Locations for USE of this Outdoor Grill Never use a match or open flame to test for gas leaks Safe USE of LP Propane GASElectrical Safety SafetyTable of Contents Additional Warnings FuelsAdditional Warnings LP Propane Gas Supply Connection Hooking Up to the LP Propane Gas Supply For Your SafetyTo Disconnect Testing For Gas LeaksNatural Gas Supply Connection To ConnectElectronic Ignition System Control FunctionsPropane Tank Valve Burner Control ValvesOperation Match Lighting the Main Burners Turning the Burners OffFlareups Match Lighting the Rotisserie Burner Lighting the Rotisserie Burner Model CF9080To start the Rotisserie burner Rotisserie Setup Optional for Model CF9050 Shutting the burner off Lighting the Side Burner Optional to Models CF9050 & CF9080Rotisserie Burner Smoker Box Using the Smoker Box Model CF9080Methods of Cooking CookingPreparing Food for the Grill Cooking. · Grilling TipsPoultry Cooking Time ChartWeight Cooking Cooking Time Type of Food BeefLamb PorkSausage Cooking Time TemperatureType of Food Cooking CommentsMain Burner Care & MaintenanceCare & Cleaning BurnersCooking Grids Rotisserie BurnerSide Burner Porcelain Enamel Castings Drip TrayStainless Steel Panels Loosen Locking Screw Turn Shutter Clockwise to Open Maintenance Burner AdjustmentAction Required Troubleshooting GuidePotential Cause Year Accessories Lifetime WarrantyYear Warranty