Description

Leading Edge air curtains produce a wall of continuously flowing air that acts as a thermal barrier against outside air and flying insects. These air curtains maintain interior conditioned temperature and prevent heated or cooled air from escaping through open doorways. They reduce humidity and loss of cold air when used over freezer and cooler doors. High traffic area doors can be left open, eliminating wear and nuisance of opening and closing automatic and manual doors. Used over service entrances, receiving doors, customer entrances, access doors, etc. ... air curtains provide protection against insects, dust, odor, fumes and other contaminant’s.

REFER TO INDIVIDUAL MODEL NUMBERS

FOR UNIT WIDTH

12

1

2

 

/

117/8

153/4

31/4

Figure 2 Dimensions

Note that all dimensions are the same on all environmental series units. Model number indicates width of unit.

(Example: E4800 indicates a 48” wide unit.)

Unpacking

1.With packaged unit on the floor, carton arrows should point upward.

2.Carefully remove staples from top of carton and fold back sides.

Specifications and Performance

 

 

MAX.

120V, 60HZ

220V, 50HZ

MAX.

AVG. CFM AT NOZZLE FOR MOTOR SHOWN

 

MAX.

MOTOR

MAX.

MAX.

FT. PER MIN.

 

IN VARIOUS CABINET SIZES

 

HP

RPM

WATTS

AMPS

AMPS

AT NOZZLE

36”

38”

42”

48”

60”*††

1/4

1100

125

3.4

.7

2500

1620

1670

1795

2000

2880

1/2

1745

480

5.2

2.2

3800

2460

2535

2730

3040

4375

3/4

1700

750

7.8

2.6

4850

3140

3240

3480

3880

5570

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

†† Two motor unit. *3/4 HP = 64” Cabinet.

Image 1
Contents Description Specifications and PerformanceUnpacking Removing Air Intake Grille General Safety InformationElectrical Connections InstallationCleaning MaintenanceOperation LubricationSymptom Possible Causes Corrective Action Troubleshooting ChartKey Part Numbers for Cabinets length Description Replacement Parts List For Air Curtain CabinetsReplacement Parts For Air Curtain Cabinets Replacement PartsFor Motor Blower Assemblies HOW to Order Repair Parts Limited Warranty