Lifebreath 120ERV, RNC120F installation manual Electrical

Page 19

Electrical

The HRV unit should be plugged into a standard designat- ed (120VAC) electrical outlet with a ground. The outlet should be serviced by a separate 15 amp/120V circuit. An extension cord should not be used with this appliance. A qualified service technician should make any required electrical connections.

Remote Control Connections

Prior to connecting remote devices, it is advisable to run self test on the HRV/ERV.

Low voltage connections between the remote controls, the dehumidistat, or the fan timer should be made by a quali- fied service technician. Low voltage wires from the remote controls are connected to the HRV micro-processor board.

WARNING

In order to prevent electric shock when cleaning or servicing the HRV, it is extremely important to confirm the polarity of the power line that is switched by the safety (disconnect) switch. The hot line (black) is the proper line to be switched. To confirm the proper polarity, use a voltmeter or test lamp to ensure there is no power after the switch when the door is open. Check between that point and ground (on the cabinet). Always make sure that the HRV is properly grounded.

19

Image 19
Contents Shipping and Packing List Required Tools Installation ToolsOptional Accessories Table of ContentsHRV System Control Engineering Data Model RNC120FOption 2 Reverse Duct Configuration Dimensions inches Engineering Data Model 120ERV Latent Recovery/Moisture Transfer CoreOption 1 Duct Configuration Dimensions Cle Installation InstructionsThat the proper fan be plugged into the proper recepta Clearances and Requirements Connecting Appliances to the HRVInstallation Weatherhood Location and InstallationFasteners not supplied Intake Weatherhood RequirementsDetail Screws supplied Indirect Connection to Air Handler Duct System Installation Air Duct Design and InstallationFresh Air Ducting Direct Connection to Air Handler Duct SystemDrain Connection HRV Only Installation Stale Air Exhaust SystemApplication Illustrations HRV-Option Partially Dedicated System for HRVAir Handler Simplified Installation for HRVFully Dedicated System for HRV Unit is normally balanced on High speed Simplified Installation for HRV Field-supplied Balancing Damper optional Minute Timer Remote Control Devices Optional Main ControlsON/OFF Switch Optional TimersDehumidistat Ventilation Control 2040 ON/OFF Dehumidistat Wiring the ControlsMinute Timer Crank TimerElectrical Operation Mode DIP Switch SettingsIncreasing Low Speed to Medium Low Wiring Diagrams Interlocking HRV Operation to an Airhandler/Furnace Blower Defrost Operation Defrost Cycle DIP Switch SettingsFactory Setting Option Dehumidistat Operation HRV onlyAir Flow Balancing Balancing ProcedurePrior to balancing, ensure that Pitot Tube Air Flow DuctMent of air in the home Troubleshooting Symptom Cause SolutionTo install the clean core MaintenanceClean Air Filters Twice a Year Clean Core Twice a Year a open access doorMaintenance Record

120ERV, RNC120F specifications

The Lifebreath RNC120F,120ERV is a highly efficient energy recovery ventilator designed to promote better indoor air quality while minimizing energy consumption. This model is ideal for a variety of residential applications, providing a cost-effective solution for ensuring a continual supply of fresh outdoor air into living spaces. The RNC120F,120ERV features advanced technologies that allow it to operate efficiently, making it a favorable choice among homeowners and building professionals alike.

One of the standout features of the RNC120F,120ERV is its energy recovery capability. This system can recover up to 85% of the energy from the outgoing stale air and transfer it to the incoming fresh air, which significantly reduces heating and cooling costs. This is particularly advantageous in regions with extreme seasonal climates, as it minimizes the demand on HVAC systems.

The unit is equipped with a high-efficiency ECM motor that operates quietly and consumes less energy compared to traditional motors. This technology not only contributes to lower energy bills but also ensures a more comfortable and peaceful indoor environment. The RNC120F,120ERV has adjustable airflow settings, allowing users to customize the level of ventilation according to their specific needs.

Another important characteristic of the Lifebreath RNC120F,120ERV is its compact design. It can easily be installed in tight spaces, making it suitable for a variety of home layouts and sizes. This versatility allows homeowners to benefit from improved air quality without sacrificing valuable living space.

The system also features a built-in filter that helps remove airborne particles, allergens, and pollutants, enhancing the overall air quality in the home. Regular maintenance and replacement of the filters are simple, ensuring that the unit continues to perform at its best.

In addition to its functional attributes, the RNC120F,120ERV is designed with durability in mind. It is constructed from high-quality materials that can withstand the rigors of continuous operation in various environments. Furthermore, the unit meets strict energy efficiency standards, making it a responsible choice for environmentally conscious consumers.

Overall, the Lifebreath RNC120F,120ERV combines energy efficiency, advanced technology, and ease of use, making it an excellent investment for anyone looking to improve their indoor air quality while keeping energy costs low.