Maintenance

HRV

 

 

1. Inspect Exterior Hoods at least once a month.

Make sure exhaust and fresh air supply hoods are not blocked or restricted by leaves, grass, or snow. In winter, it is especially important to make sure snow is not blocking the hoods or that frost has not built up on the wire mesh (bird screen).

WARNING: Blockage of hoods may cause an imbalance.

2. Clean Air Filters - Twice a Year

The standard filters equipped with your HRV are remov- able and washable.

a)simply open access door and slide core out

b)remove filters

c)rinse with water or a combination of mild soap and water. Do not clean in the dishwasher

d)to re-assemble, place clean filter(s) (wet or dry) back into their positions against the core and return clips to their original position

e)slide core back into its original position

3.Clean Core - Twice a Year a) open access door

b)rotate keeper clips and carefully grip ends of core and pull evenly outward.

-core may be snug, but will slide out of the channel

c)once removed from the cabinet remove filters

d)wash core in warm soapy water (do not use dishwasher)

e)install clean core

f)install the clean filters

Note: Core installation label on the outer end of the core.

To install the clean core:

a)first mount the bottom flange of the core guide into the bottom H channel approximately 1/4” (6mm)

b)mount the left or right side flange of the core guide approximately 1/4” (6mm) followed by the other side

c)mount the top flange of the core guide into the top H channel approximately 1/4” (6mm)

d)with all four corners in place and the core straight and even, push hard in the center of the core until the core stops on the back of the cabinet

e)rotate core clips to lock core in place

NOTE: Core will appear to stick out from cabinet approxi- mately 1/8” (3mm). This is designed this way so that the access door will fit tight against the core.

4.Motors - Maintenance Free

5.Drain (condensate) Line - Clean Once a Year

Inspect drain line, drain spout and “P” trap for blockage, mold or kinks. Flush with warm soapy water and replace if worn, bent or unable to clean.

6. Clean Duct System if Required

The duct system running to and from the HRV may accu- mulate dirt. Wipe and vacuum the duct once every year. You may wish to contact a Heating/Ventilation company to do this.

7. General Maintenance - Twice a Year

Wipe down the inside of the cabinet with a damp cloth to remove dirt, bugs and debris that may be present. Pay special attention to the drain pan and ensure water flow path is not blocked.

8. Cleaning the Fans

Fans may accumulate dirt causing an imbalance and/or excessive vibration of the HRV. A reduction in the air flow may also occur. In new construction this may result within the first year due to heavy dust and may occur periodically after that over time depending on the outdoor conditions.

unplug the HRV and open the service door

remove the core

use a small brush, such as a toothbrush or pipe cleaner, and insert first. Scrub individual fan blades until clean. Avoid moving or damaging balancing flat weight, clip is usually found on one or more of the fan blades

vacuum and wipe

Before attempting this task, thought should be given to having a qualified service technician complete the service work.

27

Image 27
Contents Shipping and Packing List Required Tools Installation ToolsOptional Accessories Table of ContentsHRV System Control Engineering Data Model RNC120FOption 2 Reverse Duct Configuration Dimensions inches Engineering Data Model 120ERV Latent Recovery/Moisture Transfer CoreOption 1 Duct Configuration Dimensions Installation Instructions CleThat the proper fan be plugged into the proper recepta Clearances and Requirements Connecting Appliances to the HRVInstallation Weatherhood Location and InstallationIntake Weatherhood Requirements Fasteners not suppliedDetail Screws supplied Indirect Connection to Air Handler Duct System Installation Air Duct Design and InstallationFresh Air Ducting Direct Connection to Air Handler Duct SystemDrain Connection HRV Only Installation Stale Air Exhaust SystemApplication Illustrations HRV-Option Partially Dedicated System for HRVAir Handler Simplified Installation for HRVFully Dedicated System for HRV Unit is normally balanced on High speed Simplified Installation for HRV Field-supplied Balancing Damper optional Minute Timer Remote Control Devices Optional Main ControlsON/OFF Switch Optional TimersDehumidistat Ventilation Control 2040 ON/OFF Dehumidistat Wiring the ControlsMinute Timer Crank TimerElectrical Mode DIP Switch Settings OperationIncreasing Low Speed to Medium Low Wiring Diagrams Interlocking HRV Operation to an Airhandler/Furnace Blower Defrost Operation Defrost Cycle DIP Switch SettingsFactory Setting Option Dehumidistat Operation HRV onlyBalancing Procedure Air Flow BalancingPrior to balancing, ensure that Pitot Tube Air Flow DuctMent of air in the home Troubleshooting Symptom Cause SolutionTo install the clean core MaintenanceClean Air Filters Twice a Year Clean Core Twice a Year a open access doorMaintenance Record

120ERV, RNC120F specifications

The Lifebreath RNC120F,120ERV is a highly efficient energy recovery ventilator designed to promote better indoor air quality while minimizing energy consumption. This model is ideal for a variety of residential applications, providing a cost-effective solution for ensuring a continual supply of fresh outdoor air into living spaces. The RNC120F,120ERV features advanced technologies that allow it to operate efficiently, making it a favorable choice among homeowners and building professionals alike.

One of the standout features of the RNC120F,120ERV is its energy recovery capability. This system can recover up to 85% of the energy from the outgoing stale air and transfer it to the incoming fresh air, which significantly reduces heating and cooling costs. This is particularly advantageous in regions with extreme seasonal climates, as it minimizes the demand on HVAC systems.

The unit is equipped with a high-efficiency ECM motor that operates quietly and consumes less energy compared to traditional motors. This technology not only contributes to lower energy bills but also ensures a more comfortable and peaceful indoor environment. The RNC120F,120ERV has adjustable airflow settings, allowing users to customize the level of ventilation according to their specific needs.

Another important characteristic of the Lifebreath RNC120F,120ERV is its compact design. It can easily be installed in tight spaces, making it suitable for a variety of home layouts and sizes. This versatility allows homeowners to benefit from improved air quality without sacrificing valuable living space.

The system also features a built-in filter that helps remove airborne particles, allergens, and pollutants, enhancing the overall air quality in the home. Regular maintenance and replacement of the filters are simple, ensuring that the unit continues to perform at its best.

In addition to its functional attributes, the RNC120F,120ERV is designed with durability in mind. It is constructed from high-quality materials that can withstand the rigors of continuous operation in various environments. Furthermore, the unit meets strict energy efficiency standards, making it a responsible choice for environmentally conscious consumers.

Overall, the Lifebreath RNC120F,120ERV combines energy efficiency, advanced technology, and ease of use, making it an excellent investment for anyone looking to improve their indoor air quality while keeping energy costs low.