Vermont Casting LHECDV20, LHERDV20 Installation & Operating Instructions, Insert Applications

Page 3

LHEDV Series Direct Vent Insert

Installation & Operating Instructions

This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment. FOR U.S. Installations follow local codes and/or the current National Fuel Gas Code ANSI Z223.1/NFPA 54.

In the Commonwealth of Massachusetts, all gas fittings and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

FOR SAFE INSTALLATION AND OPERATION OF YOUR GAS FIREPLACE PLEASE NOTE THE FOLLOWING:

1.This appliance gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.Children and adults should be alerted to the hazards of the high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing.

3.Children should be carefully supervised when they are in the same room as your appliance.

4.Under no circumstances should this appliance be modified. Parts removed for servicing should be replaced prior to operating this appliance again.

5.Installation and any repairs to this appliance should be car- ried out by a qualified service person. A professional service person should be contacted to inspect this appliance an- nually. Make it a practice to have all of your gas appliances checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.

6.Control compartments, burners and air passages in this ap- pliance should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit.

7.The venting system (chimney) of this appliance should be checked at least once a year and if needed your venting system should be cleaned.

8.Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapor and liquids. This appliance should not be used as a drying rack for cloth- ing, nor should Christmas stockings or decorations be hung in the area of it.

9.Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this appliance.

10.Whether the zero clearance kit is installed directly on carpet- ing, vinyl tile or any combustible material other than wood, this heater must be installed on a metal or wood panel extending the full width and depth of the heater. The insert can not be installed directly onto or into combustibles.

This appliance may be installed in an aftermarket per- manently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indi- cated on the rating plate.

Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufacturer before installing a television or other electronic de- vice above this fireplace.

IMPORTANT:

PLEASE READ THE FOLLOWING CAREFULLY

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated - open

all windows.

It is recommended that you burn your fireplace for at least ten

(10)hours the first time you use it. If optional fan kit has been installed, place fan in the "OFF" position during this time.

Locating Your Gas Fireplace Insert

with Zero Clearance Kit

X EAB

C

X D

X F

FP1249a

Fig. 1 Locating unit with zero clearance kit.

A)

Flat on wall

B)

Cross corner

C)

Island

D)

*Room divider

E)

*Flat on wall corner

F)

Chase installation

NOTE: (Fig. 1)

*When you install your fireplace in (D) Room divider or (E) Flat on wall corner positions, a minimum of 6 (X) inches (153mm) clearance must be maintained from the perpendicular wall and the outer edge of the trim.

Insert Applications

Before installing the gas fireplace insert, consideration must be given to the functioning needs of the fireplace. The size of the fireplace cavity (min. 25¹⁄"W x 17¹⁄"H x 13¹⁄" D (641 x 438 x 343 mm) for the LHECDV20 and LHERDV20, 28³⁄"W x 21"H x 15¹⁄"D (730 x 533 x 394 mm) for LHECDV30 and LHERDV30), the design of the chimney for effective venting should be determined. The availability of the gas supply as well as electricity for the insert fan must be confirmed.

Your Direct Vent Insert unit is designed to be vented vertically with a minimum height of 12' (4 m).

10004894

3

Image 3
Contents LHERDV30 LHECDV20 LHECDV30 Table of Contents Please Read the Following Carefully Installation & Operating InstructionsLocating Your Gas Fireplace Insert With Zero Clearance Kit Insert ApplicationsMinimum Fireplace Insert Opening Fireplace & Trim DimensionsAn alternate air supply is recommended with this component MantelsFraming & Finishing Zero Clearance ApplicationsHigh Elevations Gas Line InstallationGas Specifications Gas Inlet & Manifold PressuresFan Removal Instructions Installation of Trim Switch For RN/RP Gas ValvesGas Supply Pressures Fan KitVenting Installation Exhaust Liner InstallationMinimum Vent Height Feet Maximum Vent Height Exhaust Ceramic Refractory Installation Round Vent Termination InstallationVenting Components Operating Instructions Large Lava Rock Placement Flame Adjustment RN/RP ModelsLHECDV30, LHERDV30 Fig First Firing Flame CharacteristicsWhat to do if YOU Smell GAS To Turn Off Gas To HeaterSymptom Possible Causes Corrective Action Troubleshooting the Gas Control SystemHoneywell Millivolt Valve Instructions for RF Comfort Control Valve Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeChange Between F/C Temperature Units Delay Timer ModeAuto Mode Fan Override During Auto ModeAuto Path LED Count Service Action Replace valveLocal Path On Path Burner and Burner Compartment MaintenanceTrim Cleaning Cleaning the Standing Pilot Control SystemLhedv Series LHERDV20 LHECDV20 LHERDV30 LHECDV30 DescriptionLHER20 LHEC20 LHER30 LHEC30 LHE SeriesOptional Accessories Lhedv Series Direct Vent Insert Lhedv Series Direct Vent Insert Lhedv Series Direct Vent Insert If Warranty Service is NEEDED… Product Covered by this WarrantyAFUE% Efficiency Ratings

LHECDV20, LHERDV30, LHECDV30, LHERDV20 specifications

Vermont Castings is renowned for its commitment to offering high-quality, efficient, and aesthetically pleasing gas fireplaces. Amongst its esteemed lineup, the LHECDV20, LHERDV20, LHECDV30, and LHERDV30 stand out for their exceptional features and innovative technologies that cater to a wide range of consumer needs.

The LHECDV20 and LHECDV30 models are designed for those seeking a compact yet powerful heating solution. Both units embody Vermont Castings' signature cast-iron construction, which not only enhances durability but also provides excellent heat retention. The LHECDV20 has a smaller footprint ideal for smaller spaces, while the LHECDV30 offers a broader heating range, making it suitable for larger areas. Each model features a stunning view of the flames, achieved through large glass doors that create a warm and inviting atmosphere.

Both models utilize advanced burner technology that maximizes efficiency and minimizes emissions. The unique design ensures uniform heat distribution, which is complemented by an adjustable flame height feature. This allows you to customize the ambiance according to your preference, whether you desire a roaring fire or a gentle warmth.

The LHERDV20 and LHERDV30, on the other hand, come equipped with a realistic log set and more intricate burner systems. These units replicate the organic look of a traditional wood fire, ensuring that aesthetics do not compromise performance. The radiant heat technology in these models ensures the warmth is felt throughout the room while maintaining an eco-friendly approach to heating.

Safety features are a paramount consideration in the design of all Vermont Castings models. Each unit is equipped with an advanced safety pilot system that provides peace of mind for homeowners. Additionally, the easy-to-use remote control allows users to operate the fireplaces from the comfort of their chair, making heating your space convenient and hassle-free.

Installation is made easy with top-venting options available for each model, allowing flexibility in settings. Vermont Castings also offers an array of customizable options, enabling you to personalize your fireplace to match your home’s decor.

In summary, the Vermont Castings LHECDV20, LHERDV20, LHECDV30, and LHERDV30 gas fireplaces offer a harmonious blend of efficiency, beauty, and technology. Their commitment to quality ensures that you not only enjoy the warmth but also the elegance that these fireplaces bring to your living environment. Whether you have a cozy cabin or a spacious home, these models offer a solution to meet your heating needs while enhancing the aesthetic appeal of your space.