Mantels
When the unit is installed into a woodburning fireplace, the minimum distance the mantel can be placed above the fireplace is governed by local building codes appli- cable to woodburning fireplaces. Consult local authori- ties having jurisdiction for these clearances.
For applications requiring the use of a Zero Clearance Kit, the minimum height a mantel can be installed above the fireplace is 24" (610 mm) from the top of the upper louvres. The maximum mantel depth is 8" (203 mm). (Fig. 2)
The underside of the mantel will become warm. Use only finishes which are heat resistant and do not discolor.
24" Min. (610mm)
FP1325
Fig. 2 Minimum mantel height above fireplace.
Framing & Finishing
For Zero Clearance Kit applications, it is important to determine the finished facing material before beginning to frame. This will allow for the thickness of the finishing material between the frame and the fireplace trim.
Similarly, consideration must be given to the 1" inch depth of the air inlet channel sitting on the fireplace base. Finishing material for the hearth should be flush with the top of the air inlet channel.
If the fireplace is installed at floor level a noncombus- tible hearth must extend a minimum 12" (305 mm) in front of the fireplace.
If the fireplace is recessed into the wall and at least 12" (305 mm) above floor level, no hearth is required.
The use of wallpaper adjacent to this fire- place is not recommended as high tem- peratures given off by this fireplace may adversely effect the binders in the adhe- sive used to apply the wallpaper.
LHEDV Series Direct Vent Insert
|
| 37¹⁄₄" (946mm) |
|
| 35" |
|
|
(889mm) |
|
| |
|
| Air Inlet Channel |
|
|
| 27¹⁄₄" (692mm) | HEDVCAK is |
|
| installed outside | |
|
|
| |
| 19¹⁄₈" |
| ofthe flue pipe |
|
| only. | |
Drywall | (486mm) |
| |
|
| ||
| Finish Wall | Decorative Trim Kit | |
|
|
| FP1351 |
Fig. 3 LHEDV insert framing dimensions. |
|
NOTE: Insulating around the fireplace will result in overheating and possible malfunctioning of the circulat- ing fan.
Zero Clearance Applications
An alternate air supply is recommended with this component.
For installation other than in existing wood- burning fireplaces such as new construction or renova- tion projects, a Zero Clearance Kit must be used. The kit enables these inserts to be installed in combustible environments. Whenever using a Zero Clearance Kit, consideration must be given to the dimensions of the Zero Clearance Kit and the requirements of the Air Kit.
NOTE: If a Zero Clearance Kit is required for mod- els LHECDV20/LHERDV20/LHECDV30/LHERDV30 Direct Vent Inserts, only the CFM Corporation zero clearance kit HEZC combined with the HEDVCAK is approved to be used. Refer to Page 9, figure 10 for HEDVCAK chimney adapter kit installation. When using the HEZC with insert models LHECDV20 or LHERDV20, the Trim Closure Kit, LHE20TCK, must also be installed.