Beko CTB 6407 Connections, Ducted Version AIR Exhaust System, Recirculation Version AIR Outlet

Page 6

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø120 mm, the choice of which is left to the installer.

Fix the pipe in position using sufficient pipe clamps (not supplied).

Remove any activated charcoal filters.

RECIRCULATION VERSION AIR OUTLET

Cut a hole ø 125 mm in any shelf that may be posi- tioned over the hood.

Connect the flange to the outlet on the shelf over the hood using a flexible or rigid pipe ø120 mm.

Fix the pipe in position using sufficient pipe clamps (not supplied).

Fix the directional grille 8 on the recirculation air

outlet using the 2 screws 12e (2,9 x 9,5) provided.

• Ensure that the activated charcoal filters have been inserted.

ELECTRICAL CONNECTION

ø 120

12e

8

125

9

Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.

When opening the sliding carriage for the first time after installing the hood, pull it out briskly until it clicks.

EN

 

6

 

6

Image 6
Contents CTB 6407 CTB Index Recommendations and Suggestions InstallationMaintenance USECharacteristics ComponentsScrew Fitting InstallationDrilling the Support surface and Fitting the Hood Closing ElementRecirculation Version AIR Outlet ConnectionsDucted Version AIR Exhaust System Electrical ConnectionUSE Control panelCharcoal filter Recycling version MaintenanceGrease filters LightingPage Page Page Page Page Page Page 436005809ver1