CONVERSION OF GAS
Your cooker is designed to work with natural gas, and is convertible for use witth propane or butane.
The LPG conversion kit is available from your
Service Force Centre and must be fitted by a
Corgi Registered engineer.
For changing the gas type it is necessary to:
•replace the nozzles (hob);
•adjust the minimum level (hob);
•check the gas connection;
Fix the label supplied with the appliance (in the nozzles bag) corresponding to the gas type utilised.
SPECIFICATION NOZZLES
Table no.1
(Cat : II 2H3+)
Burner | Normal | Simmer | By- | Gas Type | Pressure | Nozzle | Cons | ||
power | power | pass | diameter |
|
| ||||
(mbar) | 3 | g/h | |||||||
| (kW) | (kW) | (mm) |
| (mm) | ||||
|
|
| m /h | ||||||
|
|
|
| Natural Gas | 20 | 1.19 | 0,267 | - | |
RAPID | 3,00 | 0,72 | 0,42 | Butane | 0,88 | - | 218,1 | ||
|
|
|
| Propane | 37 | 0,88 | - | 214,2 | |
SEMI- |
|
|
| Natural Gas | 20 | 0.96 | 0,190 | - | |
2,00 | 0,43 | 0,32 | Butane | 0,71 | - | 145,4 | |||
RAPID | |||||||||
|
|
| Propane | 37 | 0,71 | - | 142,8 | ||
|
|
|
| ||||||
|
|
|
| Natural Gas | 20 | 0.70 | 0,095 | - | |
AUXILIARY | 1,00 | 0,35 | 0,29 | Butane | 0,50 | - | 72,7 | ||
|
|
|
| Propane | 37 | 0,50 | - | 71,4 |
11