Texas Instruments TAS5103EVM, TAS5102 manual Evaluation BOARD/KIT Important Notice, FCC Warning

Page 24

EVALUATION BOARD/KIT IMPORTANT NOTICE

Texas Instruments (TI) provides the enclosed product(s) under the following conditions:

This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the product(s) must have electronics training and observe good engineering practice standards. As such, the goods being provided are not intended to be complete in terms of required design-,marketing-, and/or manufacturing-related protective considerations, including product safety and environmental measures typically found in end products that incorporate such semiconductor components or circuit boards. This evaluation board/kit does not fall within the scope of the European Union directives regarding electromagnetic compatibility, restricted substances (RoHS), recycling (WEEE), FCC, CE or UL, and therefore may not meet the technical requirements of these directives or other related directives.

Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from the date of delivery for a full refund. THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims arising from the handling or use of the goods. Due to the open construction of the product, it is the user’s responsibility to take any and all appropriate precautions with regard to electrostatic discharge.

EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.

TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive.

TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein.

Please read the User’s Guide and, specifically, the Warnings and Restrictions notice in the User’s Guide prior to handling the product. This notice contains important safety information about temperatures and voltages. For additional information on TI’s environmental and/or safety programs, please contact the TI application engineer or visit www.ti.com/esh.

No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or combination in which such TI products or services might be or are used.

FCC Warning

This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC rules, which are designed to provide reasonable protection against radio frequency interference. Operation of this equipment in other environments may cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may be required to correct this interference.

EVM WARNINGS AND RESTRICTIONS

It is important to operate this EVM within the input voltage range of 12 V to 18 V and the output voltage range of 12 V to 18 V.

Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are questions concerning the input range, please contact a TI field representative prior to connecting the input power.

Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the EVM. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.

During normal operation, some circuit components may have case temperatures greater than 80° C. The EVM is designed to operate properly with certain components above 100° C as long as the input and output ranges are maintained. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of devices can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during operation, please be aware that these devices may be very warm to the touch.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyrigh© 2008, Texas Instruments Incorporated

Image 24
Contents Users Guide Submit Documentation Feedback Contents List of Figures Additional Documentation Related Documentation From Texas InstrumentsPart Number TUSB3210SLLS466 UA78M12CKTPRSLVS059TAS5102EVM and TAS5103EVM Features PCB Key MapPower Supply Setup Electrostatic Discharge WarningUnpacking the EVM GUI Software Installation Recommended Supply VoltageRed/black Operational Sequence and Indicators Power Supply PSU Interface Pvdd and GNDRecommended Supply Voltages Loudspeaker Connectors J3 J6 J9/J10 Pin Description Amplifier/Controller ConnectorJ1 Amplifier Connection to MC012 Controller Module Output Pin DescriptionSpdif Optical Input Connector Spdif Co-Axial Input ConnectorUSB Connector Short-Circuit Protection and Fault-Reporting CircuitryHPL-MC012 Schematic I2SOUTUSBINPUT/RESET/PWMMODULATOR HPL-MC012 Composite Drawings TAS5102/3EVM Schematic Power AMPTAS5102/3EVM Composite Drawings Poweramp TAS5102/3EVM Composite Drawings Heat Sink Drawing Parts List Table A-1. Bill of Materials for HPL-MC012Description RefDes MFG Part#LED5 CMD15-21VRD/TR8LED4 CMD15-21VYD/TR8Table A-2. Bill of Materials for TAS5103EVM Table A-3. Bill of Materials for TAS5102EVM HW4 Evaluation BOARD/KIT Important Notice FCC WarningProducts Applications DSPRfid

TAS5102, TAS5103EVM, TAS5103, TAS5102EVM specifications

Texas Instruments (TI) has long been a leader in analog and embedded processing products, offering solutions that enhance audio quality and efficiency. Among their noteworthy offerings are the TAS5102 and TAS5103 digital amplifiers, as well as their corresponding evaluation modules, TAS5102EVM and TAS5103EVM. These products cater to audio professionals and enthusiasts looking for high-performance amplification solutions.

The TAS5102 is a highly efficient digital audio amplifier designed for consumer and professional audio applications. Its primary feature is its ability to deliver robust power output while maintaining low total harmonic distortion (THD) and high signal-to-noise ratio (SNR). This amplifier architecture supports various digital audio formats, making it versatile for different sound applications. The integrated design allows it to support advanced features, such as automatic shut-off and thermal protection, ensuring safe operation without compromising performance.

On the other hand, the TAS5103 takes performance a step further with enhanced output power and thermal management, making it suitable for more demanding audio applications. It integrates a high-precision PWM modulator that greatly improves audio fidelity and expands the frequency response, allowing for a richer sound experience. The TAS5103 also features differential inputs, which help in reducing noise and achieving improved sound clarity.

The TAS5102EVM and TAS5103EVM evaluation modules provide developers with a platform to assess and implement the features of the TAS5102 and TAS5103 amplifiers. These modules offer extensive interfacing capabilities and flexibility for rapid prototyping. They come equipped with power management features and a user-friendly design, allowing engineers to focus on audio design without getting bogged down by the complexity of the underlying technology. The EVMs also provide real-time diagnostic tools, enabling users to monitor performance metrics and adjust settings on-the-fly, fostering an efficient development environment.

Both the TAS5102 and TAS5103 utilize cutting-edge technology, such as Class-D amplification, which offers significant power savings compared to traditional Class A or Class AB configurations. This technology not only reduces power consumption but also minimizes heat dissipation, extending the life of the audio components. With their compact design and high-performance characteristics, these amplifiers are ideal for applications in home theater systems, soundbars, and automotive audio systems, where quality sound is paramount.

In summary, the Texas Instruments TAS5102 and TAS5103, along with their respective EVMs, represent a powerful combination of innovative design and efficient performance, making them essential components for modern audio applications. With their focus on low distortion, high efficiency, and flexibility, these amplifiers are well-suited for capturing and delivering superior audio experiences.