TROUBLE SHOOTING
CAUTION Do not open the cooker, dangerous electric voltage inside
The cookers may only be opened by authorized service personnel.
Stop any actions if the heating area (Ceran plate) is cracked or broken, the induction cooker must be switched off and disconnected from the electric supply. Don’t touch any parts inside the cooker.
Error Messages
Order of error message: The indicator lamp “ON” flashes for an interval of 0.6 sec. The number of the following short flashes has to be counted and indicating the kind of error corresponding to the following mentioned code system.
NUMBER OF FLASHING | SIGNIFICATION | NOTES | |
SIGNALS – CODE | |||
|
| ||
No fault, normal operation |
| ||
01 | No spool current, Hardware overcurrent |
| |
02 | High spool current, Software overcurrent | *** | |
|
|
| |
03 | Temperature cooling plate |
| |
04 | Temperature cooking platform, overheating | * | |
05 | Power rotary switch line break |
| |
|
|
| |
06 | Raised inside temperature |
| |
07 | Sensing element of cooking platform, short circuit | * | |
08 |
|
| |
|
|
| |
09 |
|
| |
10 |
|
| |
11 |
|
| |
|
|
| |
12 | Power reduction cooling plate temperature | ** | |
13 | Power reduction cooking platform temperature | ** | |
14 | Power reduction caused by bad pan material | ** | |
|
|
|
*The induction unit continues working but the temperature of the cooking platform is not controlled anymore.
**The induction unit continues working with reduced power cycles.
*** Bad pan material.
Part # 4020897 (01/31/08) | Page 11 |