Additional Errors
  | 
  | Problem | 
  | Possible Cause  | 
  | 
  | Measure  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Code  | No.  | 
  | No  | 
  | 
  | No  | 
  | W  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
No  | 
  | 
  | Operation lamp is continuously “ON”  | 
  | 
  | |||
  | 
  | Cooking platform does not  | 
  | 
  | 
  | 
  | Compare on another  | 
  | 
  | S20  | U10  | Non induction type pan  | 
  | M10  | cooking platform and with  | E  | |
  | heat enough  | 
  | ||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | an induction type pan  | 
  | 
  | 
  | 
  | U200  | 1 phase is missing  | 
  | M200  | Check mains cable  | L  | 
  | 
  | 
  | 
  | connection  | ||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | U12  | Power board defective  | 
  | M12  | Replace power circuit  | L  | 
  | 
  | 
  | 
  | board  | ||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | U14  | 
  | M14  | Replace   | L  | |
  | 
  | 
  | defective  | 
  | ||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Cooking platform  | 
  | Operational control  | 
  | 
  | 
  | 
  | 
  | S21  | continuously on  | U50  | 
  | M50  | Check operational control  | L  | |
  | defective  | 
  | ||||||
  | 
  | maximum power  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | U14  | 
  | M14  | Replace   | L  | |
  | 
  | 
  | defective  | 
  | ||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | U12  | Power circuit board  | 
  | M12  | Replace power circuit  | L  | 
  | 
  | 
  | defective  | 
  | board  | |||
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | S22  | Empty cooking platform  | U220  | Pan detection defective  | 
  | M220  | Check pan detection  | L  | 
  | switches “on“  | 
  | ||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Little metallic objects are  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | S23  | heated on the cooking  | U220  | Pan detection defective  | 
  | M220  | Check pan detection  | L  | 
  | 
  | platform  | 
  | 
  | 
  | 
  | 
  | 
  | 
No.  | 
  | 
  | 
  | Operation lamp flashes | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | S24  | Cooking platform does not  | U240  | Pan too small (Diameter  | 
  | M240  | Use appropriate pan  | E  | 
  | heat at all  | less than 12cm, 4.75”)  | 
  | |||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | U200  | 1 phase is missing  | 
  | M200  | Check connection of  | L  | 
  | 
  | 
  | 
  | mains cable  | ||||
  | 
  | 
  | U220  | Pan detection defective  | 
  | M220  | Check pan detection  | L  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | U241  | Short circuit on generator  | 
  | M241  | Replace or repair  | L  | 
  | 
  | 
  | 
  | generator  | ||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Legend: W = Who should complete “Measure”  | E = End user L = Supplier  | 
  | 
  | 
  | ||||