Error Messages
LED 8 | LED 7 | LED 6 | Code | Signification | NOTE |
— | — | — | — | No error, normal function |
|
— | — | On | 01 | No coil current, overdrive caused by non induction pan |
|
— | On | — | 02 | High coil current, overdrive by non induction pan |
|
— | On | On | 03 | Temperature heat sink too high |
|
On | — | — | 04 | Temperature heating area (coil) too high | 1 |
On | — | On | 05 | Potentiometer defected , wiring disconnected |
|
On | On | — | 06 | Temperature inside the unit too high |
|
On | On | On | 07 | Heating area – coil sensor short circuit | 2 |
— | — | — | 08 |
|
|
— | — | — | 09 |
|
|
— | — | — | 10 | Communication error (serial interface) |
|
— | — | — | 11 |
|
|
— | — | — | 12 |
|
|
— | — | — | 13 |
|
|
— | — | — | 14 |
|
|
— | — | — | 15 |
|
|
|
|
|
|
|
|
1.The induction unit can only be started again if the fault has been acknowledged (turn power rotary knob “off“)
2.The induction unit continues working but the temperature of the cooking platform is not controlled anymore.
Part # 4526029 (02/22/11) | Page 7 |