Adjustments
This induction unit has been correctly adjusted by the manufacturer. Any adjustments have to be made with caution. Please pay attention to the following points:
1.Note the original position of the poti’s: remember the number of turns you make.
2.Errors can occur after wrong adjustments
3.Only small corrections can be made with adjustments
Generator Type
The generator type is adjusted in the binary code with the
Switch Position
8 | 7 | 6 | 5 | ||
generator type | |||||
|
|
|
| ||
|
|
|
|
| |
0 |
|
|
|
| |
1 |
|
|
| ON | |
2 |
|
| ON |
| |
|
|
|
|
| |
3 |
|
| ON | ON | |
4 |
| ON |
|
| |
5 |
| ON |
| ON | |
|
|
|
|
| |
6 |
| ON | ON |
| |
7 |
| ON | ON | ON | |
8 | ON |
|
|
| |
|
|
|
|
| |
9 | ON |
|
| ON | |
10 | ON |
| ON |
| |
11 | ON |
| ON | ON | |
|
|
|
|
| |
12 | ON | ON |
|
| |
13 | ON | ON |
| ON | |
14 | ON | ON | ON |
| |
|
|
|
|
| |
15 | ON | ON | ON | ON |
Switch Power
Summary: software and generator type
The following list shows the number of types of the various generators.
Please note the positions of the power switches from the above table.
Type | DIP | |
Switch setting | ||
| ||
MO/DU 7000, 208V | 6 and 8 on | |
MO/DU 7000, 400V | 5 and 8 on |
Pan detection
The potentiometer on the rectifier circuit board is used to adjust the pan detection:
Turn clockwise: | acceptance of smaller pans |
Turn counterclockwise: only bigger pans are accepted
Power
Only one potentiometer per field is available on the power circuit board to adjust the power:
Turn clockwise: | less power |
Turn counterclockwise: more power
Repair by Garland
If the generator has to be repaired by the manufacturer, please enclose an exact description of the error. If possible, use the original package for the return. If it isn’t available, do not use porous material for wrapping (like styropor). This could enter the unit and the electronic parts and is difficult to remove.
Page 14 | Part # 4526029 (02/22/11) |