Dimensional Diagrams
25" | 25" |
|
WITH TELESCOPIC CHIMNEY KIT | WITH FULL WIDTH DUCT COVER |
The Pro Magnum can be vented to the top or directly out the back. Make your ductrun as straight and short as possible. The ductrun should not exceed 35 equivalent feet if ducted with 3 1/4” by 10” rectangular duct or 55 equivalent feet if ducted with 10” round ductwork (when using Duct Transition Kit 6000002 for 48” model only). Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º flat elbows as 12 feet.
For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24” of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood’s exhaust opening as possible.
48” MODEL
Hole for Wiring Cable
30” AND 36” MODELS
Hole for Wiring Cable
Hole for Wiring Cable
OPTIONAL DUCT TRANSITION KIT DIMENSIONS (48”MODEL ONLY)
93/4”
2 | 5/8” | 23 1/4” |
| ||
|
| 22 1/4” |
|
| 1/2” |
|
| 3 3/8” | Rectangular Hole which fits over the two 3 1/4” x 10” | 4 3/8” |
|
| exhaust openings on the rangehood | ||
|
|
|
| |
|
| 14” |
|
|
|
| 1/2” |
|
|
|
|
| 1/2” |
|
4” |
|
|
|
|
1/2” | 3 3/8” | 1/2” |
|
|
For 48” model, use two 3 1/4” by 10” rectangular duct runs or use the optional Duct Transition Kit shown here. This kit cannot be used with the Telescopic Chimney Cover because it is too large to fit behind the cover. The Duct Transition Kit will fit behind the Full Width
Duct Cover. | Rev.06/08 |
WARNING! Product specifications are subject to change without notification. Consult the installation instructions before you begin installing this rangehood.