Desa (V)DVC36(B)(H), (V)DVC42(B)(H) installation instructions Corner Installation

Page 11

Venting Installation instructions

Continued

CORNER INSTALLATION

Recommended Applications:

Corner ground floor installation

Ground floor installation where pipe vents horizon- tally through wall (over 12" horizontal pipe)

Basement installation where one foot clearance from ground to termination is possible

Not to Exceed (H) Limits

90° Elbow

 

Square

As Required

Termination

for (V), See

 

 

Chart for

 

Pipe Section

 

Required

Wall

 

Firestop

 

Not to Exceed

(H)Limits 90° Elbow

Wall

Firestop

45° Elbow

Square Termination

12" Min.

45° Elbow

 

Required

 

Vertical (V)

Vertical Pipe

Horizontal (H)

*43 1/2" min.

None

30" max.

54 1/2" min.

1 ft.

48" max.

66 1/2" min.

2 ft.

60" max.

78 1/2" min.

3 ft.

84" max.

90 1/2" min.

4 ft.

20' max.

* Ground Floor Corner Venting

Figure 15 - Horizontal Termination Configuration for Corner Installation Using One

90° Elbow

SNORKEL TERMINATION INSTALLATION

Recommended Applications:

Installations requiring a vertical rise on building exterior

Any installation using snorkel termination to achieve one foot above ground

Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termination below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure 16). Do not back fill around snorkel termination.

Snorkel

Termination

 

Snorkel Termination

Wall

 

 

Firestop

Snorkel Termination

90° Elbow

12"

Min.

12" Min.

12" Min.

45° Elbow

Adequate

Drainage

Figure 16 - Snorkel Termination Configurations for Below Ground Installation

118197-01C

www.desatech.com

11

Image 11
Contents Patent Pending For Use with DVM series Burner modulesSafety Information Table of ContentsProduct Identification Product FeaturesLocal Codes Proper clearances must be maintained Pre-Installation PreparationLocation and space requirements ClearancesClearances for Combustible Mantels Balcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsBy cutting, twisting, bending, etc Location of the fireplaceUse wall straps for this purpose To be twist-locked onto the flue collar asInstalling Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Corner InstallationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Vertical Venting Desa 5/8 Pipe & Vent Kits Number Description Replacement PartsParts list for venting kits and components Parts Under WarrantyAccessories Technical ServiceModels VDVC36BH and VDVC42BH Illustrated Parts BreakdownParts List Keep this Warranty Warranty Information

(V)DVC36(B)(H), (V)DVC42(B)(H) specifications

Desa (V)DVC36(B)(H) and (V)DVC42(B)(H) are distinguished products in the realm of innovative heating solutions, specifically engineered for residential and commercial environments. These direct vent gas fireplaces combine traditional aesthetics with modern technology to provide users with both comfort and efficiency.

One of the main features of the (V)DVC36 model is its ability to deliver significant heat output while maintaining a sleek and stylish design. It boasts an impressive heat capacity, making it an ideal choice for spaces that require a dependable source of warmth. Additionally, the unit's dimensions strike a balance between form and function, ensuring it fits beautifully within a variety of interior layouts.

Similarly, the (V)DVC42 model advances this concept with a larger size that facilitates even greater heat output. It caters to bigger rooms and open-concept spaces, ensuring that warmth is evenly distributed. Both models are equipped with advanced ceramic glass technology which enhances efficiency by allowing maximum heat transfer into the room while maintaining safety and visibility of the flames.

Another noteworthy characteristic of these models is their direct venting system. This technology allows for the safe expulsion of exhaust gases while drawing in fresh air for combustion. The result is a cleaner operation with minimal emissions, making them a more environmentally friendly choice compared to other heating options. The direct vent design also minimizes drafts, contributing to overall comfort within the living space.

In addition to their efficiency, the Desa (V)DVC36(B)(H) and (V)DVC42(B)(H) fireplaces come equipped with user-friendly controls. These features allow for easy operation, enabling users to adjust the flame height and heat output to suit their specific needs. The intuitive design ensures that even those new to gas fireplaces can enjoy the benefits without a steep learning curve.

Furthermore, both models can be customized with various decorative options, including different media types like logs, pebbles, or crystals, allowing homeowners to tailor their fireplace to their individual style.

In summary, the Desa (V)DVC36(B)(H) and (V)DVC42(B)(H) fireplaces exemplify the intersection of elegance, technology, and efficiency. Offering robust heat output, direct venting for safety, and customizable aesthetics, they represent a valuable addition to any home or commercial space looking to merge comfort with sophistication.