Desa (V)DVC42(B)(H) Location of Termination Cap, Balcony with Perpendicular Side Wall

Page 6

Location of Termination Cap

D

E V

B L

 

C

 

 

Fixed

V

 

Closed

 

 

F

Openable

 

V

 

B

B

B

Openable ClosedFixed

H

VI

B

V J XG

AM

N N

 

G

 

V

 

G

V K X

V

 

 

 

 

 

 

 

 

 

 

 

A

 

 

V TERMINATION CAP

X AIR SUPPLY INLET

 

G

GAS METER

 

 

RESTRICTED AREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TERMINATION PROHIBITED)

A

=

clearance above grade, veranda, porch, deck, or

I

=

clearance to service regulator vent outlet [*72" (182.9 cm)

 

 

balcony [*12" (30.5 cm) minimum]

 

 

 

minimum]

 

 

 

B

=

clearance to window or door that may be opened

J

=

clearance to non-mechanical air supply inlet to building

 

 

[6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US

 

 

or the combustion air inlet to any other fireplace

 

 

if between 10,000 and 50,000, 12" (30 cm) in Canada

 

 

[6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US

 

 

if between 10,000 and 100,000; 12" (30 cm) in US if

 

 

if between 10,000 and 50,000, 12" (30 cm) in Canada

 

 

greater than 50,000, 36" (91 cm) in Canada if greater

 

 

if between 10,000 and 100,000; 12" (30 cm) in US if

 

 

than 100,000]

 

 

 

greater than 50,000, 36" (91 cm) in Canada if greater

C

=

clearance to permanently closed window

 

 

 

than 100,000]

 

 

 

 

 

[minimum 12" (30.5 cm) recommended to prevent

K

=

clearance to a mechanical air supply inlet [*In Canada,

 

 

condensation on window]

 

 

 

6 ft. (1.83m) minimum; In US 3 ft. (91 cm) above if within

D

=

vertical clearance to ventilated soffit located above the

 

 

10 ft. (3 m) horizontally]

 

 

 

 

 

terminal within a horizontal distance of 24" (61 cm) from L

=

† clearance above paved side-walk or a paved driveway

 

 

the center-line of the terminal [18" (45.7 cm) minimum]

 

 

located on public property [*84" (213.3 cm) minimum]

E

=

clearance to unventilated soffit [12" (30.5 cm) minimum] M =

clearance under veranda, porch, deck

F

=

clearance to outside corner (see below)

 

 

 

[*12" (30.5 cm) minimum ‡]

G

=

clearance to inside corner (see below)

 

N =

clearance above a roof shall extend a minimum of

H

=

*not to be installed above a meter/regulator assembly

 

 

24" (61 cm) above the highest point when it passes

 

 

within 36" (91.4 cm) horizontally from the center line

 

 

through the roof surface and any other obstruction within

 

 

of the regulator

 

 

 

a horizontal distance of 18" (45.7 cm)

vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

Outside Corner

Recessed Location

A

V

A = 6" (15.2 cm)

V

B = 6" (15.2 cm)

B

 

D

C

C

E

V

Balcony with No Side Wall

G

V

G = 12" (30.5 cm) minimum clearance

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (61 cm)

J = 20" (50.8 cm)

C = Maximum depth of 48" (121.9 cm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965 mm) Noncombustible - 24" (61 cm)

E = Clearance from corner in recessed location- Combustible - 6" (15.2 cm) Noncombustible - 2" (5.1 cm)

Figure 7 - Minimum Clearances for Termination Cap

www.desatech.com118197-01C

Image 6
Contents For Use with DVM series Burner modules Patent PendingTable of Contents Safety InformationProduct Features Local CodesProduct Identification Clearances Pre-Installation PreparationLocation and space requirements Proper clearances must be maintainedClearances for Combustible Mantels Location of Termination Cap Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsTo be twist-locked onto the flue collar as Location of the fireplaceUse wall straps for this purpose By cutting, twisting, bending, etcInstalling Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Round TerminationCorner Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Installation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting Parts Under Warranty Replacement PartsParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionTechnical Service AccessoriesIllustrated Parts Breakdown Models VDVC36BH and VDVC42BHParts List Warranty Information Keep this Warranty

(V)DVC36(B)(H), (V)DVC42(B)(H) specifications

Desa (V)DVC36(B)(H) and (V)DVC42(B)(H) are distinguished products in the realm of innovative heating solutions, specifically engineered for residential and commercial environments. These direct vent gas fireplaces combine traditional aesthetics with modern technology to provide users with both comfort and efficiency.

One of the main features of the (V)DVC36 model is its ability to deliver significant heat output while maintaining a sleek and stylish design. It boasts an impressive heat capacity, making it an ideal choice for spaces that require a dependable source of warmth. Additionally, the unit's dimensions strike a balance between form and function, ensuring it fits beautifully within a variety of interior layouts.

Similarly, the (V)DVC42 model advances this concept with a larger size that facilitates even greater heat output. It caters to bigger rooms and open-concept spaces, ensuring that warmth is evenly distributed. Both models are equipped with advanced ceramic glass technology which enhances efficiency by allowing maximum heat transfer into the room while maintaining safety and visibility of the flames.

Another noteworthy characteristic of these models is their direct venting system. This technology allows for the safe expulsion of exhaust gases while drawing in fresh air for combustion. The result is a cleaner operation with minimal emissions, making them a more environmentally friendly choice compared to other heating options. The direct vent design also minimizes drafts, contributing to overall comfort within the living space.

In addition to their efficiency, the Desa (V)DVC36(B)(H) and (V)DVC42(B)(H) fireplaces come equipped with user-friendly controls. These features allow for easy operation, enabling users to adjust the flame height and heat output to suit their specific needs. The intuitive design ensures that even those new to gas fireplaces can enjoy the benefits without a steep learning curve.

Furthermore, both models can be customized with various decorative options, including different media types like logs, pebbles, or crystals, allowing homeowners to tailor their fireplace to their individual style.

In summary, the Desa (V)DVC36(B)(H) and (V)DVC42(B)(H) fireplaces exemplify the intersection of elegance, technology, and efficiency. Offering robust heat output, direct venting for safety, and customizable aesthetics, they represent a valuable addition to any home or commercial space looking to merge comfort with sophistication.