Desa (V)DVC36(B)(H), (V)DVC42(B)(H) Venting Installation Instructions, Installation Precautions

Page 7

Venting Installation

Instructions

NOTICE: Read these instruc- tions completely before at- tempting installation.

These models are tested and approved for use with DESA (direct-vent) pipe components and terminations.

The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance.

These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the fol- lowing guidelines:

When venting system terminates horizontally on an outside wall, you may install a standoff if the termination cap is to be installed directly on a combustible finish such as vinyl, wood, stucco, etc.

Never run the vent downward as this may cause excessive temperatures which could cause a fire.

Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which requires 2" clearance from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required.

Snorkel terminations are required when minimum clearance to grade cannot be met (see Figure 16 on page 11).

Have fireplace and selected vent components on hand to help determine the exact measurements when elbowing or offsetting. Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces.

If using a venting configuration of only hori- zontal venting with no vertical run, a 1/4" rise for every 12" of run toward the termination is required.

For installation of fireplace at elevations of 4000 feet or greater, pay special attention to venting requirement recommendations.

WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life.

NOTICE:Failuretofollowthesein- structions will void the warranty.

NOTICE: Do not seal termination cap to vent pipe. Cap must be removable for vent inspection and maintenance.

Installation Precautions

Wear gloves and safety glasses for protection

Use extreme caution when using ladders or when on roof tops

Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting system:

Installation of any damaged venting component

Unauthorized modification of the venting sys- tem (Do not cut or alter vent components)

Installation of any component part not manu- factured or approved by DESA

Installation other than as instructed by these instructions

WARNING: This gas fireplace andventassemblymustbevented directlytotheoutside.Theventing system must NEVER be attached to a chimney serving a separate solidfuelburningappliance.Each direct-vent gas appliance must useaseparateventsystem.Donot use common vent systems.

WARNING: Vent pipe air spaceclearancestocombustibles are 1" on all sides except on the horizontalsections,whichrequire 2" clearances from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required.

118197-01Cwww.desatech.com

Image 7
Contents Patent Pending For Use with DVM series Burner modulesSafety Information Table of ContentsLocal Codes Product FeaturesProduct Identification Proper clearances must be maintained Pre-Installation PreparationLocation and space requirements ClearancesClearances for Combustible Mantels Balcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsBy cutting, twisting, bending, etc Location of the fireplaceUse wall straps for this purpose To be twist-locked onto the flue collar asInstalling Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Corner InstallationHorizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting Desa 5/8 Pipe & Vent Kits Number Description Replacement PartsParts list for venting kits and components Parts Under WarrantyAccessories Technical ServiceModels VDVC36BH and VDVC42BH Illustrated Parts BreakdownParts List Keep this Warranty Warranty Information

(V)DVC36(B)(H), (V)DVC42(B)(H) specifications

Desa (V)DVC36(B)(H) and (V)DVC42(B)(H) are distinguished products in the realm of innovative heating solutions, specifically engineered for residential and commercial environments. These direct vent gas fireplaces combine traditional aesthetics with modern technology to provide users with both comfort and efficiency.

One of the main features of the (V)DVC36 model is its ability to deliver significant heat output while maintaining a sleek and stylish design. It boasts an impressive heat capacity, making it an ideal choice for spaces that require a dependable source of warmth. Additionally, the unit's dimensions strike a balance between form and function, ensuring it fits beautifully within a variety of interior layouts.

Similarly, the (V)DVC42 model advances this concept with a larger size that facilitates even greater heat output. It caters to bigger rooms and open-concept spaces, ensuring that warmth is evenly distributed. Both models are equipped with advanced ceramic glass technology which enhances efficiency by allowing maximum heat transfer into the room while maintaining safety and visibility of the flames.

Another noteworthy characteristic of these models is their direct venting system. This technology allows for the safe expulsion of exhaust gases while drawing in fresh air for combustion. The result is a cleaner operation with minimal emissions, making them a more environmentally friendly choice compared to other heating options. The direct vent design also minimizes drafts, contributing to overall comfort within the living space.

In addition to their efficiency, the Desa (V)DVC36(B)(H) and (V)DVC42(B)(H) fireplaces come equipped with user-friendly controls. These features allow for easy operation, enabling users to adjust the flame height and heat output to suit their specific needs. The intuitive design ensures that even those new to gas fireplaces can enjoy the benefits without a steep learning curve.

Furthermore, both models can be customized with various decorative options, including different media types like logs, pebbles, or crystals, allowing homeowners to tailor their fireplace to their individual style.

In summary, the Desa (V)DVC36(B)(H) and (V)DVC42(B)(H) fireplaces exemplify the intersection of elegance, technology, and efficiency. Offering robust heat output, direct venting for safety, and customizable aesthetics, they represent a valuable addition to any home or commercial space looking to merge comfort with sophistication.