Dimensional Diagrams
Ducted | Ductless |
Ducted
| upper |
| 2 3/4” | min |
|
|
|
|
| |||||
| chimney |
|
|
|
|
|
| |||||||
|
| 15 3/8” max |
|
|
|
|
| |||||||
| cover |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| lower |
|
|
|
|
|
|
|
|
|
|
| ||
| chimney |
| 23 5/8” |
|
|
|
|
|
|
| ||||
| cover |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
| canopy |
|
| 2 3/8” |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
x=distancefromhoodtocooktop |
|
|
|
|
| min & max ceiling | height examples |
| ||||||
|
|
|
| |||||||||||
|
|
|
| x = 24" | x = 26" | x = 28" | x = 30" | |||||||
(varies depending on installation) |
| x | ||||||||||||
min - 24”, suggested max - 30” |
|
| min | min | min | min | ||||||||
also consult cooktop |
|
|
|
| 7' 4 3/4" | 7' 6 3/4" | 7' 8 3/4" | 7' 10 3/4" |
| |||||
manufacturer's recommendation |
|
|
|
|
| max | max | max | max | |||||
|
|
|
|
|
|
|
| 8' 5 3/8" | 8' 7 3/8" | 8' 9 3/8" | 8' 11 3/8" |
| ||
|
|
|
|
|
|
|
| |||||||
cabinet base |
| 36” |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ductless
upper |
|
|
|
|
|
|
|
| 8 3/8” min |
|
|
|
|
| ||||
chimney |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
cover |
|
|
|
|
|
|
|
| 15 3/8” max |
|
|
|
|
| ||||
ductless |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
lower |
|
|
| 3 1/2” |
| 23 5/8” |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||||
chimney |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
cover |
| 12 1/2" |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| canopy |
|
| 2 3/8” |
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
x=distancefromhoodtocooktop |
|
|
|
|
| min & max ceiling | height examples |
| ||||||||||
|
|
|
| |||||||||||||||
|
|
|
| x = 24" | x = 26" | x = 28" | x = 30" | |||||||||||
(varies depending on installation) |
| x | ||||||||||||||||
min - 24”, suggested max - 30” |
|
| min | min | min | min | ||||||||||||
also consult cooktop |
|
|
|
| 7' 10 3/8" | 8 3/8" | 8' 2 3/8" | 8' 4 3/8" |
| |||||||||
manufacturer's recommendation |
|
|
|
|
| max | max | max | max | |||||||||
|
|
|
|
|
|
|
|
|
|
|
| 8' 5 3/8" | 8' 7 3/8" | 8' 9 3/8" | 8' 11 3/8" |
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||||||
| cabinet base |
| 36” |
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The ducted Stilo Isola chimney can be adjusted for ceilings between 7’ 4 3/4” and 8’ 11 3/8” depending on the distance between the bottom of the hood and the cooktop (distance x in above DUCTED diagram). The ductless Stilo Isola chimney can be adjusted for ceilings between 7’ 10 3/8” and 8’ 11 3/8” depending on the distance between the bottom of the hood and the cooktop (distance x in above DUCTLESS diagram). For higher ceiling installations, the High Ceiling Chimney Kit includes an additional support structure which
adds 27 1/2" to the various ceiling heights in the figures above. | Ductless Installations |
Pre-Planning Your Ductwork - Important: Consult the
installation instructions before you begin installing this rangehood.
Make your ductrun as straight and short as possible. The ductrun should not exceed 35 equivalent feet if ducted with the required minimum of 6” round ductwork. Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º flat elbows as 12 feet.
For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24” of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood’s exhaust opening as possible.
WARNING! Product specifications are subject to change without notification. begin installing this rangehood.
For installations where ductwork is impossible or highly impractical, a Ductless Conversion Kit is available. Charcoal filters, which attach to the blower assembly, absorb smoke and odors. A ductless diverter directs the air out to a lower chimney with vent grates cut into the sides.
*it is highly recommended that professional style cooking always be
vented to the outside. | Rev.06/08 |
Consult the installation instructions before you |