Installation
1.Slide the right
2.Hook the outside edge of the baffle over the top of the secondary air chamber. This will make room to for the installation of the left
3.Slide the left
4.Pull the baffles together in the middle so the right tab rests on top of the left tab. Ensure the baffles are flush with the back and both sides of the firebox.
Note for insert models only: If the bolts on the flue collar are not to the left and right of the hole, the front secondary air tube will need to be removed in order to install or remove the
Right Ceramic Baffle |
Left Ceramic Baffle |
Figure 23: Installation of C-Cast Ceramic Baffle.
FAN WIRING DIAGRAMS:
This appliance, when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA.
CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
DO oil the fan bearings regularly.
DO NOT cut or remove the grounding prong from the plug.
DO NOT route the power cord beneath the heater.
WARNING: This appliance is equipped with a
23