Hearth and Home Technologies BH 105 manual Control Board Operation

Page 24

Operation

WATER TEMPERATURE

MAX. TEMP.

MIN. TEMP.

Control Board Operation

Aquastat Sensor - This sensor is located in the aqua- stat well on the top of the water jacket. This sensor along with the outdoor air sensor is what the control board uses to regulate the feed rate based on these two observed conditions. (Boiler Temp. & Outdoor Air Temperature)

Outdoor Air Temp. Sensor (OAT) - This sensor is located outside the building (on the north side of the house and out of direct sunlight). The Outdoor Air Sensor is used to perform hot water reset based on out- door air temperatures.

When the OAT sensor is installed, at 20° F. or below (outside temperature), the boiler will operate at the temperature set on the MAX. TEMP. knob. The boiler water temperature will decrease by 1 degree F. for every 1 degree F. in temperature rise (above 20°) of the outdoor air.

NOTE: Pellet Boiler Outdoor Air Reset Operation Graph located on page 23.

Setting The Boiler Temperature

Without the Outdoor Air Temperature Sensor Installed

To set the maximum boiler water temperature, sim- ply turn the Max. Temp. water temperature dial to the desired setting. The control and the boiler will then perform to achieve and maintain the set temperature. The Min. Temp. Knob is the boiler water tempera-

ture minimum, or the lowest temperature the water will go before the unit re-starts. Turning the knob fully counter-clockwise is the “OFF” position, while turn- ing the knob clockwise, past the 140 degree marking, is the “ON” position..

With The Outdoor Air Temp - Sensor Installed Maximum boiler temp setting is as described above. The MIN. TEMP. knob in addition to being the

mode setting (on or off) now also has the function of setting the minimum boiler water temperature. This would be the lowest boiler water temperature that you want to have based on the following factors.

1.) Outdoor Air Temperature (OAT)

2.) Domestic Hot Water Use

a.) Hot Water Coil Option

b.) Indirect Hot Water Storage 3.) Overall Volume of the Heating System

The boiler is designed to withstand lower return water temperatures however, extended return temperatures below 140 degrees F can cause condensation in the secondary ash chamber area and also in the venting system, which could cause damage in these areas.

NOTE:

If the system is run at the lower temperature settings, con- ditions of the firebox, boiler tubes, secondary ash chamber and venting should be monitored closely. If conditions show excess condensation, the boiler water minimum tempera- ture will need to be increased until condensation does not occur. You should also consider some form of tempering of the return water system. Discuss this with your plumber.

24

Image 24
Contents Installation & Operating Manual BH 105 Pellet BoilerPage Parts Locations Table Of Contents IntroductionWarranty ECO-CHOICE Limited WarrantyAssembly Boiler Kit Materials Refer toDesign Installation is to be Performed by a Qualified Installer Venting Venting Ventingti g VentingVenting Installation Keep combustibles away From flue outletOutside Air Main Wiring Installation InstallingInstallationDuct Installing Duct/AirInstallationConditioning Installation Example of Typical Tankless Domestic HOT Water PipingUnion AIR Vent Installation Over Heat Safety Zone Power Failure / Heat Dissipation LoopDraft Test Procedure TestFuel Specifications Fuel and Fuel StorageOperation Status LightWithout the Outdoor Air Temperature Sensor Installed Control Board OperationPellet Boiler Outdoor Air Reset Operation Turn Mode Selector to OFF Starting a Fire AutomaticallyFlip the Igniter Switch up into the Auto position MAX. TempLighting a Fire Manually Have matches or other ignition source readyOperation Maintenance Burnpot CleaningFeeder Chamber Fig To remove the feeder coverOpen Ash Door Remove Ash PanCleaning Steps Combustion Blower Cleaning Troubleshooting Helpful HintsFuel Atmospheric Conversion Bh105 #8 Ash base Assembly Stocked at depot #28 Feeder Assembly #29 boiler Kit #30 water Plate Kit #31 handle Kit Description COmmENTS PArT NumbEr Hardware Packages Specifications BTU Input Range= 0, and 9350 to 113,900Electrical 120 VAC 60 Hz Diagram Pellet Boiler Wiring DiagramPower Failure Backup Supply Testing Label BH105Service Record / Notes Proudly Printed On 100% Recycled Paper Quick Reference Auto-Light Signature of Boxer

BH 105 specifications

Hearth and Home Technologies BH 105 is a modern and versatile fireplace that combines functionality and aesthetic appeal. Designed for both residential and commercial spaces, it brings the warmth of a traditional fireplace with the convenience of contemporary technology. One of the standout features of the BH 105 is its impressive heating capacity, efficiently warming larger areas while maintaining a cozy atmosphere.

The BH 105 uses advanced combustion technology, which not only maximizes heat output but also minimizes emissions, making it an eco-friendly choice for homeowners. This fireplace achieves a commendable efficiency rating, ensuring that most of the heat generated is utilized effectively, reducing energy costs and environmental impact.

Aesthetically, the BH 105 offers a sleek and contemporary design that can seamlessly blend with any decor. The large viewing area features tempered glass, providing unobstructed views of the mesmerizing flames. This visual aspect enhances the ambiance of any room, making it a focal point in the home. The fireplace is available in various finishes, allowing homeowners to choose a style that complements their personal taste and existing interior designs.

User experience is a priority in the BH 105’s design. It includes features such as an easy-to-use control panel and a programmable thermostat that allows for precise temperature regulation. This user-friendly interface enables individuals to set their desired comfort levels with ease.

The BH 105 also comes equipped with safety features like an automatic shut-off system, ensuring peace of mind for users, especially in households with children or pets. The durability of the materials used in its construction ensures that the fireplace can withstand the rigors of regular use while maintaining its aesthetic charm.

In summary, Hearth and Home Technologies BH 105 is a perfect embodiment of modern fireplace technology, offering high efficiency, stunning design, and user-friendly features. Whether for heating a living room or creating a cozy atmosphere in a commercial setting, the BH 105 stands out as an exceptional choice for discerning individuals seeking warmth without compromising on style.